Changeset 6408 for trunk/MagicSoft/TDAS-Extractor
- Timestamp:
- 02/12/05 17:16:04 (20 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/MagicSoft/TDAS-Extractor/Criteria.tex
r5783 r6408 1 \section{Criteria for the Optimal Signal Extraction }1 \section{Criteria for the Optimal Signal Extraction (STILL TO DO!!)} 2 2 3 \subsection{Resolution (amplitude and time)} 4 \ldots {\textit{In this section, the jitter to exactly identical input pulses is measured, for times, amplitudes, 5 high-gain and low-gain pulses }} 6 \begin{itemize} 7 \item Jitter to pulpo pulses \ldots Hendrik 8 \item Comparing MC signal with and w/o noise of different intensity \ldots Nuria 9 \item Jitter to pedestals (of different intensity) \ldots Hendrik 10 \item Comparing the low-gain to high-gain ratio for different intensities \ldots Markus 11 \item Derive the time jitter to calibration pulses \ldots Maxim ??? 12 \end{itemize} 13 14 \subsection{Bias} 15 \ldots {\textit In this section, the bias of the extractor for low and high intensities is defined and measured } 16 \begin{itemize} 17 \item Bias to pedestals (of different intensity) \ldots Hendrik 18 \item Comparing MC signal with and w/o noise of different intensity \ldots Nuria 19 \end{itemize} 20 21 \subsection{Signal to Noise} 22 \ldots {\textit In this section, the signal to noise of an extractor is determined, for times and amplitudes 23 \newline \ldots Maxim ???, Thomas ???} 3 \subsection{Resolution and Bias} 4 \ldots {\textit{The jitter to identical input pulses is measured, for times, amplitudes, 5 high-gain and low-gain pulses and different signal and background levels }} 24 6 25 7 \subsection{Stability} 26 \ldots {\textit In this section, the stability of an extractor to slightly varying pulse shapes is examined. }8 \ldots {\textit The stability of an extractor to slightly varying pulse shapes is examined. } 27 9 \begin{itemize} 28 10 \item Stability w.r.t. different weights files \ldots Hendrik … … 33 15 34 16 \subsection{Linearity} 35 \ldots {\textit In this section, the Nuria plots are examined \newline \ldots Nuria}17 \ldots {\textit The Nuria plots ... } 36 18 37 19 \subsection{Treatment of Calibration Pulses} … … 39 21 secondary pulses, possible secondary pulses from hadronic showers and the typical Cherenkov 40 22 pulses are extracted by the different extractors and typical dependencies examined, like the 41 Razmik plot, the number of photo-electrons with number of slices, comparisons between different colours, etc. 42 \newline \ldots Hendrik??? , Markus??? + ????} 23 Razmik plot, the number of photo-electrons with number of slices, comparisons between different colours, etc.} 43 24 44 25 \subsection{Low Gain Extraction} 45 \ldots {\textit In this section, the stability of the low-gain extraction w.r.t. the high-gain extraction is 46 examined. Useful plots are still to be defined. 47 \newline \ldots Arnau ????} 26 \ldots {\textit The stability of the low-gain extraction w.r.t. the high-gain extraction} 48 27 49 28 \subsection{Applicability for Different Sampling Speeds / No Pulse Shaping.} 50 \ldots {\textit In this section, some comments of Hendrik will be made}29 \ldots {\textit Some comments by Hendrik ...} 51 30 52 31 \subsection{CPU Requirements} 53 \ldots {\textit In this section, the needed CPU time is measured for each extractor independently } 54 \newline \ldots {\textit ALL (after all)} 55 32 \ldots {\textit The needed CPU time for each extractor} 56 33 57 34 %%% Local Variables: 58 35 %%% mode: latex 59 36 %%% TeX-master: "MAGIC_signal_reco" 60 %%% TeX-master: "MAGIC_signal_reco"61 37 %%% End:
Note:
See TracChangeset
for help on using the changeset viewer.