Changeset 6630 for trunk


Ignore:
Timestamp:
02/19/05 17:11:59 (20 years ago)
Author:
gaug
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/TDAS-Extractor/Calibration.tex

    r6629 r6630  
    803803
    804804\begin{enumerate}
    805 \item Intrinsic transit time spread TTS of the PMT. It can be in the order
     805\item The intrinsic arrival time spread of the photons on the PMT. This time spread
     806can be estimated roughly by the intrinsic width of the calibration pulses of about 2\,ns
     807for the faster UV pulses and 3--4\,ns for the green and blue pulses. It amounts to
     808
     809For our
     810calibration LEDs this can be up to about 2 ns, for muons it is about a
     811few hundreds of ps and for hadrons a few ns. The error of the mean
     812arrival time of the total pulse is again the arrival time spread of the
     813photons divided by the number of photo electrons.
     814\item The intrinsic transit time spread TTS of the PMT. It can be in the order
    806815of a few hundreds of ps per single photo electron. When we reconstruct
    807816the mean pulse arrival time the error of the mean is given by the time
    808817spread per single photo electron dividid by the square root of number of
    809818photo electrons.
    810 \item Intrinsic arrival time spread of the photons on the PMT. For our
    811 calibration LEDs this can be up to about 2 ns, for muons it is about a
    812 few hundreds of ps and for hadrons a few ns. The error of the mean
    813 arrival time of the total pulse is again the arrival time spread of the
    814 photons divided by the number of photo electrons.
    815819\item reconstruction error due to noise and error of the numeric fit in
    816820case of the digital filter. In case of the digital filter the error for
Note: See TracChangeset for help on using the changeset viewer.