Ignore:
Timestamp:
02/19/05 17:15:42 (20 years ago)
Author:
gaug
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/TDAS-Extractor/Calibration.tex

    r6630 r6631  
    804804\begin{enumerate}
    805805\item The intrinsic arrival time spread of the photons on the PMT. This time spread
    806 can be estimated roughly by the intrinsic width of the calibration pulses of about 2\,ns
    807 for the faster UV pulses and 3--4\,ns for the green and blue pulses. It amounts to
     806can be estimated roughly by the intrinsic width $\delta t_{\mathrm{LED}}$
     807of the calibration pulses of about 2\,ns
     808for the faster UV pulses and 3--4\,ns for the green and blue pulses. The resulting time
     809resolution is given by:
     810\begin{equation}
     811\Delta t \approx \frac{\delta t_{\mathrm{LED}}}{\sqrt{Q/{\mathrm{phe}}}}
     812\end{equation}
     813
    808814
    809815For our
Note: See TracChangeset for help on using the changeset viewer.