Ignore:
Timestamp:
02/21/05 20:46:53 (20 years ago)
Author:
gaug
Message:
*** empty log message ***
Location:
trunk/MagicSoft/TDAS-Extractor
Files:
2 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/TDAS-Extractor/MAGIC_signal_reco.tex

    r6651 r6657  
    3636%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
    3737\title{Comparison of Signal Reconstruction Algorithms for the MAGIC Telescope}
    38 \author{H. Bartko, M. Gaug, F. Goebel, A. Moralejo, \\
    39 M. Shayduk, N. Sidro, W. Wittek}
    40 \date{February 28$^{\mathrm{th}}$, 2005\\}
    41 \TDAScode{MAGIC-TDAS 05-xx\\ 050228}
     38\author{H. Bartko, M. Gaug, F. Goebel, A. Moralejo,\\
     39Th. Schweizer, M. Shayduk, N. Sidro, W. Wittek}
     40\date{February 21$^{\mathrm{st}}$, 2005\\}
     41\TDAScode{MAGIC-TDAS 05-xx\\ 050221}
    4242%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
    4343
     
    5252are described and compared. Criteria for comparison are defined and used to judge the
    5353different extractors applied to calibration signals, cosmics and pedestals. At the end,
    54 a digital filter fitting the signal over four FADC slices is proposed as the best extractor.
    55 The question of pedestal calculation for the different extractors is adressed. The digital filter
    56 is used to extract and fit single photo-electron pulses from the night sky background.
     54extractors are recommended for the most conservative and the most advanced and demanding analyses.
     55It is shown that the digital filter
     56can be used to extract and fit single photo-electron pulses from the night sky background.
     57The achievable time resolution can be parameterized to be:
     58\begin{equation}
     59\Delta T_{\mathrm{cosmics}} \approx \sqrt{\frac{(2\,\mathrm{ns})^2}{<Q>/{\mathrm{phe}}}
     60+ \frac{(4.5\,\mathrm{ns})^2}{<Q>^2/{\mathrm{phe^2}}} + (0.2\,\mathrm{ns})^2} . \nonumber
     61\label{eq:time:fitprediction}
     62\end{equation}
     63For galactic backgrounds an image cleaning threshold as low as 5~photo-electrons can be achieved
     64for rejecting 99.7\% of noise.
    5765\end{abstract}
    5866
  • trunk/MagicSoft/TDAS-Extractor/Results.tex

    r6623 r6657  
    444418  & Slid. W. (4,4)       & \ok & \ok & \ok & \ok & \ok & \ok & \no & \no & \no & \ok \\   
    454519  & Slid. W. (4.6)       & \ok & \ok & \ok & \ok & \ok & \ok & \ok & \no & \ok & \ok \\   
    46 20  & Slid. W. (6,6)       & \no & \ok & \ok & \ok & \ok & \ok & \no & \ok & \ok & \ok \\   
    47 21  & Slid. W. (8,8)       & \no & \ok & \ok & \ok & \ok & \ok & \ok & \ok & \ok & \ok \\   
    48 22  & Slid. W. (14,10)       & \no & \no & \ok & \ok & \ok & \ok & \no & \ok & \ok & \ok \\   
     4620  & Slid. W. (6,6)       & \no & \ok & \ok & \ok & \ok & \ok & \no & \ok & \ok & \best \\   
     4721  & Slid. W. (8,8)       & \no & \ok & \ok & \ok & \ok & \ok & \ok & \ok & \ok & \best \\   
     4822  & Slid. W. (14,10)       & \no & \no & \ok & \ok & \ok & \ok & \no & \ok & \ok & \best \\   
    4949\hline                               
    505023  & Spline Ampl.           & \ok & \no & \no & \no & \nt   & \ok & \ok   & \no & \no & \ok \\
Note: See TracChangeset for help on using the changeset viewer.