    r6869 r6870  
    5656   * mjobs/MJStar.cc:
    5757     - replaced MCerPhotEvt by MSignalCam
     58
     59   * msignal/cosmics_weights46.dat, msignal/calibration_weightsUV46.dat,
     60     mjobs/hilocalib_df46.root:
     61     - added
     62
     63  * mbase/MLogHtml.cc:
     64     - fixed a bug in Underline which cause a crash if fOut==NULL
     65     - output a message if file cannot be opened
     66
     67   * mhcalib/MHCalibrationPulseTimeCam.cc:
     68     - for some output there was a replacement of pix.GetPixId()
     69       by hist.GetName() <undocumented>
    5870
    5971
     
    178190     - removed MFSelStandard
    179191     - removed MFSelFinal
     192
     193
     194
     195 2005/03/19 Markus Gaug
     196 
     197   * mjobs/hilocalib_df46.root
     198     - added new intercalibration file for digital filter 4sl higain
     199       and 6 slices logain
     200
     201   * mjobs/MJCalibration.cc
     202      - exchanged intercalibration file from hilocalib_df_4.root to 
     203        hilocalib_df46.root
     204
     205   * mjobs/MJPedestal.cc
     206     - exchanged two (Int_t)'s by TMath::Nint().
     207     - undocumented(!) change to the calculation of the extraction
     208       range (PulsePosCheck)
     209
     210   * callisto.rc
     211     - exchanged default weights file for Digital filter from
     212       cosmics_weights4.dat to cosmics_weights46.dat and from
     213       calibration_weights_UV4.dat to calibration_weights_UV46.dat!
     214       This change is absolutely necessary, given the new results from
     215       Nuria about the signal resolution in the low gain which gets worse
     216       than the intrinsic Poisson jitter above 350 phes. Also the time
     217       resolution is too bad. This was not known before we had the 
     218       correct low-gain MC pulse.
    180219
    181220
Note: See TracChangeset for help on using the changeset viewer.