Changeset 6880 for trunk/MagicSoft/Mars/NEWS
- Timestamp:
- 03/23/05 10:11:43 (20 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/MagicSoft/Mars/NEWS
r6875 r6880 1 1 -*-*- END -*-*- 2 *** Version <cvs> 2 3 *** Version 0.9 (2005/03/23) 3 4 4 - Calibration is now done autmatically into equiv.photo-electrons like5 - Calibration is now done autmatically into photo-electrons like 5 6 decided by the Collaboration Board 6 7 … … 9 10 - Interlaced calibration events can be handled by callisto 10 11 11 - Hi gh-Gain vs. Low-Gain calibration constants can be calculated12 (but not yet applied)in callisto.12 - Hi-Gain vs. Lo-Gain calibration constants can be calculated 13 and applied in callisto. 13 14 14 15 - class MJCalibTest can be called by callisto 15 16 - interpolated pointing positions are now in Tree "Events" after17 calibration18 16 19 17 - callisto can now run with three data types: rawdata, rootdata, MC … … 66 64 extracted with the signal extractor with randomization 67 65 66 - callisto now finds the pulse position in the data automatically 67 68 68 - implemented data reduction in calibrated data by reducing the precision 69 69 of the stored floating point values (pedestal, rms and signal) to … … 91 91 * needs less storage space 92 92 93 94 95 96 97 98 99 100 101 93 - FIRST version which can process Monte Carlos through the 94 whole chain of programs (callisto, star, etc) 95 96 - implemented new image parameters for the border length of 97 the shower image (MNewImagePar2) 98 99 - implemented wobble-mode in ganymed 100 101 - new class (MJOptimize) taking care of all optimization processes 102 102 103 103
Note:
See TracChangeset
for help on using the changeset viewer.