Ignore:
Timestamp:
07/21/05 17:45:25 (19 years ago)
Author:
tbretz
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/NEWS

    r7204 r7205  
    9393     photo-electrons for the spline extractor by 1-2% (correctly).
    9494
     95   - callisto: The intercalibration is now done using a full f-factor
     96     method instead of a simple update. This makes things slower but
     97     more reliable in terms of gain-fluctuations and sudden VCSEL gain
     98     changes.
     99
     100   - callisto: MPedestalY3 now uses the same extraction range as the data
     101     as calculated by MPedestalY2
     102
     103   - callisto: A check of the fraction of allowed unsuitable (10%) and
     104     unreliable (30%) pixels has been addded when the conversion is
     105     calculated from interleaved events
     106
    95107   - star: fixed a bug which caused MEffectiveOnTime containers not to
    96108     be written. In the worst case they were skipped almost all, in the
     
    103115   - star: corrects now (correctly?) for the misspointing in May/April 05
    104116
     117   - star: Output now contains MReportStarguider
     118
    105119   - ganymed: Two new default templates for ganymed.rc are avilable:
    106120              ganymed_onoff.rc and ganymed_wobble.rc
    107121
    108    - ganymed: The first version of MFMagicCuts have been released
     122   - ganymed: The first version of MFMagicCuts has been released
    109123
    110124   - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
     
    116130   - ganymed: optimized palettes for MHDisp
    117131
    118    - ganymed: MPedestalY3 now uses the same extraction range as the data
    119      as calculated by MPedestalY2
    120 
    121    - ganymed: A check of the fraction of allowed unsuitable (10%) and
    122      unreliable (30%) pixels has been addded when the conversion is
    123      calculated from interleaved events
    124 
    125132   - ganymed: Fixed an important bug when using ThetaSq as fit function:
    126133     The result for the sigma of the gauss(sqrt(x)) fit was a factor
    127134     sqrt(2) to large
    128135
    129    - ganymed: The intercalibration is now done using a full f-factor
    130      method instead of a simple update. This makes things slower but
    131      more reliable in terms of gain-fluctuations and sudden VCSEL gain
    132      changes.
    133 
    134136   - ganymed: The false source plot (MHDisp) is now based on Disp
    135      and a background model determied in the first loop is
     137     and a background model determined in the first loop is
    136138     subtracted
     139
     140   - ganymed: MFMagicCuts are now available in the cvs. The correct
     141     solution for the disp ambiguity problem is now calculated using
     142     the third moment. The third moment cut therefor is skipped.
     143
     144   - ganymed: Output now contains "Disp [MParameterD]" which sign is
     145     already determined by the third moment along the major axis and
     146     so its actual sign is aligned along the major axis of the shower.
    137147
    138148   - sponde: the zenith angle distribution is now weighted instead of
Note: See TracChangeset for help on using the changeset viewer.