     20 2005/11/29 Thomas Bretz
     21
     22   * mmain/MEventDisplay.cc:
     23     - added a MContinue to be setup by mars.rc to the tasklist to
     24       allow to choose events
     25
     26   * mars.rc:
     27     - added an example how to use the new cut
     28
     29
     30
    2031 2005/11/28 Thomas Bretz
    2132
     
    90101
    91102   * msignal/MExtractTimeAndChargeDigitalFilter.cc
    92      - fix a bug in the calculation of the high-gain times:
    93        They were all shifted by the same amount "fHiGainFirst". This
    94        caused an offset of usually 3 FADC slices in the times calculated
    95        from high-gain and from low-gain. The bug did not have any effect
    96        on the calibration runs because there, fHiGainFirst was set to 0.
    97        The bug was there since 30.1.2005.
     103     fixed a bug in the calculation of the high-gain times:
     104     They were all shifted by the same amount "fHiGainFirst". This
     105     caused an offset in the order of the position of the left border of
     106     the extraction window in the times calculated from high-gain and
     107     from low-gain. The bug was there since 30.1.2005.