    r816 r817  
    273273digital output.
    274274
    275 The first-level-trigger is looking in the digital output of the
    276 271 pixels of the trigger system for next neighbor (NN) conditions. 
    277 The adjustable settings on the first-level-trigger
     275The first-level-trigger checks in the digital output of the
     276271 pixels of the trigger system for next neighbor (NN)
     277conditions. 
     278The adjustable settings of the first-level-trigger
    278279are the mulitiplicity, the topology and the minimum required
    279280overlapping time.
    280281
    281 
    282 The MC data produced are used to calculate some important
    283 parameter of the MAGIC telescope on the level of the
    284 trigger system.
    285 
    286 The second-level-trigger of the MAGIC telescope will be a
    287 pattern-recognition method. This part is still in the design
    288 phase. All results presented here are based on studies of the
    289 first-level-trigger.
     282The second-level-trigger of the MAGIC telescope will be based
     283on a pattern-recognition method.
     284This part is still in the design phase.
     285All results presented here are based on studies of the
     286first-level-trigger. It not mentioned somewhere else,
     287the MC data are produced with "standard"
     288values (discriminator threshold = 4 mV, gate length = 6 nsec,
     289multiplicity = 4, topology of NN = {\sl closed package}).
     290
    290291
    291292 
    292293\subsubsection{Collection area}
     294
     295
    293296
    294297The trigger collection area is defined as the integral
     
    296299  A(E,\Theta)  = \int_{F}{ T(E,\Theta,F) dF}
    297300\end{equation}
    298 where T is the trigger probablity. F is perpendicular to
    299 the shower axis. The results for different zenith angle $\Theta$ and
     301where T is the trigger probablity. F is a plane perpendicular
     302 to the shower axis.
     303The results for different zenith angle $\Theta$ and
    300304for different discriminator thresholds are shown in figure
    301305\ref{fig_collarea}.
     306At low energies ($ E < 100 ~\mathrm{GeV}$), the collection area
     307decreases with increasing zenith angle , and it decreases with
    302308%
    303309%
     
    314320%
    315321%
    316 As bigger the zenith angle the smaller becomes the collection area
    317 for lower energies. As bigger the discriminator threshold is set, as
    318 lower is the trigger collection area for low energies.
     322increasing diskriminator threshold.
    319323 
    320324
     
    322326
    323327The threshold of the MAGIC telesope is defined as the peak
    324 in the $dN/dE$ distribution. For all different trigger settings
     328in the $dN/dE$ distribution for triggered showers.
     329For all different trigger settings
    325330this value is determined. The energy threshold could
    326 depend among other variables on the Background simulated conditions,
     331depend among other variables on the background conditions,
    327332the threshold of the trigger discriminator and the zenith angle. We
    328 check the influence of the three above-mentioned variables.
     333check the influence of these three variables.
    329334
    330335For both, gammas and protons, some different background conditions
    331336have been simulated (without any background light, diffuse light,
    332 and light from Crab Nebula field of view). The results pointed out
    333 that there is not any variation of the energy threshold inside our
    334 error, which is few GeV, in determining the maximum. It is
    335 worth to remember that this is based only in first level trigger.
    336 Most likely there will be some effects when one enters the second
     337and light from Crab Nebula field of view).
     338No significant variation of the energy threshold is observed.
     339It should be stressed that this is based only on first level
     340triggers.
     341Most likely some effects will be seen after the second
    337342level trigger and the shower reconstruction.
    338343
    339 Magic will do observations in a large range of zenith angles,
    340 therefore is worth to study the energy threshold as function of
    341 the zenith angle. In figure \ref{fig_enerthres}, it is shown for 0, 5
    342 and 10 degrees. Even though larger statistic is needed, the energy
    343 threshold increases slowly with the zenith angle.
     344MAGIC will do observations in a large range of zenith angles,
     345therefore it is worth studying the energy threshold as function of
     346the zenith angle (see figure \ref{fig_enerthres}).
     347Even though larger statistic is needed, the energy
     348threshold increases slowly with the zenith angle, as expected.
    344349\begin{figure}[hb]
    345350 \vspace*{2.0mm} % just in case for shifting the figure slightly down
     
    353358photons in the camera plane are needed to trigger the Telescope.
    354359And it helps the low energy showers to fulfil the required trigger
    355 conditions. In figure  \ref{fig_enerthres} one can see that the threshold
    356 energy decreases  while lowering the discriminator. It is 29 GeV for 3 mV
    357 and 105 GeV  for 7 mV. Since one of the aims of the Telescope is lowering as
    358 much as possible the energy threshold, a low discriminator value is
    359 preferred. But for 3 mV the expected rate due to protons increases a
     360conditions.
     361In figure  \ref{fig_enerthres} one can see that the threshold
     362energy decreases when lowering the discriminator.
     363It is 29 GeV for 3 mV and 105 GeV  for 7 mV.
     364Since we are aiming for a low energy threshold,
     365a low discriminator value is  preferred.
     366However, for 3 mV the expected rate due to protons increases a
    360367lot (see section ~\ref{sec-rates}), while it keeps under control at 4 mV.
    361 Therefore, the threshold of the discriminator would be kept above
    362 4 mV, which yields a energy threshold of 45 GeV.
     368Therefore, the threshold of the discriminator would be kept around
     3694 mV, which yields an energy threshold of 45 GeV.
    363370
    364371\subsubsection{Expected rates}\label{sec-rates}
Note: See TracChangeset for help on using the changeset viewer.