  • trunk/MagicSoft/Mars/Changelog

    r8215 r8217  
    1818
    1919                                                 -*-*- END OF LINE -*-*-
     20 2006/12/04 Thomas Bretz
     21
     22   * mcalib/MCalibrationChargeCalc.cc:
     23     - fixed a typo in a console message
     24
     25
    2026
    2127 2006/11/16 Daniela Dorner
  • trunk/MagicSoft/Mars/NEWS

    r8214 r8217  
    182182     not be opened.
    183183
    184    - callisto: In some rare cases it could happen that in the hi-gain
     184   - callisto: In some rare cases it could happen that in the signal
    185185     extraction of the digital filter the extractor returned nonsense
    186      results due a wrong initializion of a variable
     186     results due a wrong initializion of a variable (this happens in
     187     cases in which the extracted signal is exactly zero or the
     188     digital filter couldn't slide because of a too small extraction
     189     window, which could happen in the lo-gain extraction)
    187190
    188191   - callisto: The lo-gains have been marked as valid in some cases
     
    195198
    196199   - callisto: fixed a bug which caused the hi-gain saturation not
    197      to be handled properly
     200     to be handled properly in the spline (the position of the
     201     saturation was calculated incorrectly)
    198202
    199203   - callisto: fixed a bug which gave weird results if hi- _and_
    200      lo-gain could not be extracted properly
     204     lo-gain could not be extracted properly. In some cases hi-
     205     and lo-gain have not been extracted at all and the random result
     206     got calibrated. In other cases the hi-gain was saturating and the
     207     lo-gain has not been extracted. For this a completly arbitraty
     208     scale factor was applied to the result from extracting the
     209     charge of the saturating hi-gain.
    201210
    202211   - callisto: improves handling of extracted signal if lo- and/or
     
    207216   - callisto: Fixed a problem in the spline extraction which gave
    208217     weird results if the signal was extracted from the first (and
    209      highest) slice
     218     highest) slice (as a workaround extraction from the first
     219     slice has been forbidden)
    210220
    211221   - callisto: Fixed a bug regarding the use of the QE which doesn't
     
    213223     (The bug was there since 14/07/2005)
    214224
    215    - callisto: Changed the default for fgLoGainStartShift
     225   - callisto: Changed the default for fgLoGainStartShift to -2.4
    216226
    217227   - callisto: Fixed a bug which caused all hi-/lo-gain calibration
  • trunk/MagicSoft/Mars/mcalib/MCalibrationChargeCalc.cc

    r8147 r8217  
    11/* ======================================================================== *\
    2 ! $Name: not supported by cvs2svn $:$Id: MCalibrationChargeCalc.cc,v 1.170 2006-10-23 12:27:21 tbretz Exp $
     2! $Name: not supported by cvs2svn $:$Id: MCalibrationChargeCalc.cc,v 1.171 2006-12-04 14:22:29 tbretz Exp $
    33! --------------------------------------------------------------------------
    44!
     
    10661066  if (!fExtractor)
    10671067    {
    1068       *fLog << err << "Extractor resolution has been chosen, but not extractor is set. Cannot calibrate." << endl;
     1068      *fLog << err << "Extractor resolution has been chosen, but no extractor is set. Cannot calibrate." << endl;
    10691069      return kFALSE;
    10701070    }