Ignore:
Timestamp:
11/12/08 16:16:11 (16 years ago)
Author:
tbretz
Message:
*** empty log message ***
File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/MagicSoft/Mars/NEWS

    r9145 r9157  
    22
    33== <cvs> ==
     4
     5 ;SUGGESTION
     6
     7   * This release doesn't contain a major changed which is expected to
     8     change your result. Nevertheless there are small changes to
     9     the calibration which can effect at least the first few hundred
     10     events in any (mainly MUX and even more SUM) sequence a little bit.
     11     So it is recommended although not necessary to reset your sequences
     12     in the database before  further processing.
    413
    514 ;general
     
    4453     quite weak. Now sum events pass the calculation if and only if they
    4554     have also a level 1 trigger.
     55
     56   * the extraction of pedestal events and pulse position from the
     57     first data events is now more automatic and makes sure that
     58     a more precise number of events is extracted independent of
     59     the ratio with which pedestal events or events with signals
     60     are contained in the data.
    4661
    4762 ;ganymed
Note: See TracChangeset for help on using the changeset viewer.