Version 7 (modified by 6 years ago) ( diff ) | ,
---|
This is an overview of the most important tables and some important remarks. Links are given to the comments and type of each column.
RunType
Source
RunInfo
The RunInfo table is the most important one. It stored run-wise information. In a first step, a lot of data is directly extracted from the header of the raw run-files. Later, values are calculated from other sources, mainly slow-control file (auxiliary data: aux) and filled into the table as well.
Calculating the on-time
The best estimate for the on-time of the data acquisition is the difference between the first and last event (fRunStop-fRunStart
). It should be precise with roughly the data rate, so better than 1s. The on-time calculated by the FTM is only precise with the FTM rate which is a few seconds, but the FTM provides accurate information on the relative on-time w.r.t. to the total time. This information can be used to calculate the on-time in seconds of a run as follows:
TIME_TO_SEC(TIMEDIFF(fRunStop,fRunStart))*fEffectiveOn
Events
--- not yet available ---
Position
--- not yet available ---
AnalysisResultsRunISDC
factdata/AnalysisResultsRunISDC
The number of background events (fNumBgEvts
) is already divided by the number of wobble regions (5).
To calculate the signifciance, you can simply do LiMa(fNumSigEvts, fNumBgEvts). To calculate the statistical error, use
ExcErr(fNumSigEvts, fNumBgEvts)`. Both function assume that the number of background events given is the average number and that the scale factor is 5.