wiki:DatatakingLimits

Version 13 (modified by dneise, 11 years ago) ( diff )

use explicit imperatives following ​https://tools.ietf.org/html/rfc2119

Back to DataTakingMainPage

Observation Limits

value max action
​ Zenith angle ~88° reschedule
​median current per pixel in camera 115 uA reschedule or stop
​maximum current in a single pixel 160 uA reschedule or stop
​ Clouds no stars visible in pointing direction reschedule or stop
​ abs(T_GAPD - T_ambient) 15° C stop
​ T_container 40° C stop
​ Wind speed 50km/h stop
Rain stop
​ water on mirrors stop

"stop or reschedule"?

reschedule
In case it seems possible to observe another source, the shifter should try that. Also the SpecialMeasurements should be taken into consideration.
stop
The shifter must stop the normal observation mode, by scheduling the task named Sleep on the ​ scheduler page for right now. This brings the system into a safe state.

ToDo

  • Explain how to check currents for alternative sources using smartfact.
  • Apply a filter to the wind speed, in order to convert the condition "significantly or in regular intervals" into a simple yes/no decision. A low pass, or maybe integrator should do fine here.
Note: See TracWiki for help on using the wiki.