Version 9 (modified by 9 years ago) ( diff ) | ,
---|
Back to DataTakingMainPage
when you reach these Limits: STOP DATATAKING!
value | max | action |
median current per pixel in camera | 115 uA | stop or reschedule |
maximum current in a single pixel | 160 uA | stop or reschedule |
abs(T_GAPD - T_ambient) | 15° C | stop |
T_container | 40° C | stop |
Zenith angle | ~88° | stop or reschedule |
Wind speed | exceeds 50km/h significantly or in regular intervals | stop |
Clouds | no stars visible in pointing direction | stop or reschedule |
Rain | it is raining | stop |
clouded mirrors/water on mirrors or light pulser | stop |
"stop or reschedule"?
- stop
-
Stop the normal observation mode, by scheduling the task named
Sleep
on the scheduler page for right now. This brings the system into a safe state and the shifter has time to think.
- reschedule
- In case it seems possible to observe another source, because e.g. another source is less obscured by clouds, the shifter is of course free to try that.
Also sometimes SpecialMeasurements can be done.
ToDo
- Explain how to check currents for alternative sources using smartfact.
Note:
See TracWiki