after a power cut
restart hardware
- contact the MAGIC shift crew to switch gate back on
- email adress of the MAGIC shifters:
magic_shifters@mpp.mpg.de
- phone numbers for MAGIC shift crew: http://www.magic.iac.es/contacts/, login with user "FACT" and the usual password
- email adress of the MAGIC shifters:
- go to https://trac.fact-project.org/wiki/TroubleShootingComputers and switch the other computers back
- before you do any software trouble shooting: go to http://10.0.100.100/ to check if the pump is working, the bias power is enabled and the cooling liquid flow meter is measuring enough throughput. In case some of it aren't, go to http://10.0.100.232/ and http://10.0.100.238/ and switch BIAS, LID and PUMP back on. Go to http://10.0.100.100/ to switch the camera back on.
restart software
- now the software has to be restarted according to (https://trac.fact-project.org/wiki/TroubleShootingSoftware)
- version for dummies (you can quit the screen session with Ctrl+a and d):
1) ssh fact@newdaq
2) screen -x => will probably say "There is no screen to be attached".
3) screen -c /home/fact/.screenrc_newdaq
4) ssh fact@gate
5) screen -x => will probably say "There is no screen to be attached".
6_A) /users needs to be mounted, 'sudo mount -a'
6_B) screen -c /users/fact/.screenrc_gate
7) ssh fact@newdata 8) screen -x => probably no screen 8) screen -x .screenrc_newdata 7) ssh fact@aux
8) screen -x => will probably say "There is no screen to be attached".
9) screen -c /home/fact/.screenrc_aux
10) (still on aux) ps aux | grep vnc => if no vnc is running => vncserver :1
11) use a software like vinagre to log into the newly created vnc session: vinagre aux:1
12) to start the tpoint camera gui, in a terminal: cd /home/fact/Drive.new/FACT++ and then ./tpoint
- check in smartfact http://fact-project.org/smartfact, whether the systems are all in a correct state (lid closed, fad control connected, etc.)
- if not, send the corresponding commands in the screen session on newdaq
IMPORTANT
In case the telescope was operated while the power cut happened => make sure the telescope gets parked manually (TODO: link) if the observation should not be continued!!!'''