source: trunk/MagicSoft/Mars/NEWS@ 9432

Last change on this file since 9432 was 9429, checked in by tbretz, 16 years ago
*** empty log message ***
File size: 133.2 KB
Line 
1 -*-*- END -*-*-
2
3== <cvs> ==
4
5 ;general:
6
7 * Added a new palette "temp" to MH::SetPalette which should resample
8 a temperature
9
10 ;showplot:
11
12 * If a file without a MStatusArray is opened all object (not just
13 canvases) found in the file are drawn. Note that this may result
14 in empty tabs.
15
16 ;ceres:
17
18 * The night sky noise is now scaled with the sensitive area and
19 is given in units per square centimeter
20
21 * Added the possibility to add a cut after the image parameter
22 calculation (''Cut'')
23
24 * updated the PDE of the GAPDs with a more reliable curve from
25 the meeting page (linear extrapolate below 350nm)
26
27 * The impact distribution in the event distrbutions is now
28 perpendicular to Alt/Az and the histogram is displayed in 1D
29
30 * The GAPD PDE has been updated
31
32 * PDEs and mirror reflectivities have been linearily extrapolated
33 to match the wavelegth range between 290nm and 900nm
34
35 * There is no default pulse shape anymoe it must be given in
36 the resource file
37
38 * Fixed a bug which caused the aerosol coefficient to be incorrectly
39 initialized. The effect might be random.
40
41 ;callisto:
42
43 * Fixed a bug which prevented MAGIC Monte Carlo file from being
44 calibrated (ceres files worked)
45
46 ;ganymed:
47
48 * added new starguider calibration for sequences since 1000534
49
50
51
52== Version 2.3 (2009/03/07) ==
53
54 ;SUGGESTION
55
56 * There is no need to re-run any data because no change took place which
57 could have an effect on the output. However, if you want a
58 meaningful SrcPos plot for your MCs in sponde you must re-process
59 star for your MCs first.
60
61 ;REMARK
62
63 * File produced with this release containing a camera geometry (which
64 are basically all files were produced as default) will not be readable
65 by older releases.
66
67 ;general
68
69 * fixed a few small bugs which could cause the display to crash in ganymed
70 and sponde
71
72 * in sequence file the date can now be omittet. In this case the
73 leading date with the underscore is missing in the expected filename
74
75 * the geometry class now also supports other geometries than just hexagons
76
77 ;automation
78
79 * added magnetic field Azimuth direction (ARRANG), currently
80 at ~ -7deg at La Palma
81
82 ;database
83
84 * plotdb.php: added default (sequences) for startup, added possibility
85 to set size of plot
86
87 * added a new table ''RunDataCheck'' which containes the rates after
88 image cleaning for every run which succeeded star. It can be
89 plotted using ''plotrundb.C''
90
91 ;merpp
92
93 * added support for Arehucas Version >= 200812140
94
95 * added support for Arehucas Version >= 200809030
96
97 ;mars
98
99 * The display now also displays the trigger pattern
100
101 * The display can now display ceres reflector (_R_) files
102
103 ;ceres
104
105 * added a uniformly distributed one-bin time jitter for the start of the
106 digitization. Otherwise the first photon would be digitized always with
107 the same alignment to the bins
108
109 * Added a plot showing the production height of the photons
110
111 * Moved the particle id from the event header to the run header
112
113 * Added the possibility to simulate a psf on the camera plane (MSimPSF)
114
115 * Added a new plot ''SignalMax'' showing the maximum entry into the pixels
116
117 * Added many new options to control the tasks. For deatils see ''ceres.rc''
118
119 * Removed obsolete plots in pedestal and calibration mode
120
121 * Removed the non-NightSky photons from the plots where they are just
122 disturbing
123
124 * Added a trigger pattern to the output (Ped, Cal or Lvl1)
125
126 * The daq event number now represents the readout number
127
128 * The camera ''electronics'' can now be ''switched off''
129
130 * A new tab ''Info'' now display basic things like the reflector
131 layout
132
133 * Improved reading speed for corsika files
134
135 * Improved memory handling (if a large ampount of memory was needed
136 for a single event all further events were stored in the same
137 memory and it was never freed, so the program took this memory
138 until the end)
139
140 * Converted the code from MMCS' reflector program to MSimAtmosphere
141 (instead of the tables build in for MAGIC Winter and Summer
142 atmosphere we use the values written by Corsika fitted to the
143 tabulated atmosphere given as input)
144
145 * For caluclating the displayed image parameters in ceres a basic
146 image cleaning removing isolated pixels is now done.
147
148 * The magnetic field direction (ARRANG) is now taken into account
149
150 * Added plot for the energy threshold after trigger ''Threshold''
151
152 * Added plot for the effective collection area after trigger ''TrigArea''
153
154 ;star
155
156 * Now outputs MSrcPosCam for Monte Carlos in the Events tree.
157
158 * The definition of fConcCore has slightly changed. The numbers
159 might decrease a little bit (the effect should be rather small)
160
161 ;ganymed
162
163 * added pointing model 328198
164
165 ;sponde
166
167 * The SrcPos plot for your MCs was so far meaningless because it just
168 displayes the MSrcPosCam data from the input star-files. Unfortunately,
169 this containes was never written to the star-files yet.
170
171 * A new Tab 'OnTime' is available which is an effective on-time
172 fit as in star but for all data. This is mainly for manual cross-check
173 of the effective on-time
174
175 * In some circumstances it might be necessary to re-calculate the
176 eff. on-time from the fit in the new tab, e.g. when a zenith distance
177 cut was made in ganymed. This can now be forced by ''--force-ontimefit''
178
179 * now reads the ''ganymed.rc'' from the ''ganymed.root'' and writes
180 it to its own output file (for convinience)
181
182
183
184== Version 2.2 (2009/01/30) ==
185
186 ;SUGGESTION
187
188 * This release doesn't contain a major change which is expected to
189 change your results. Nevertheless there are small changes to
190 the calibration which can effect at least the first few hundred
191 events in any (mainly MUX and even more SUM) sequence a little bit.
192 So it is recommended although not necessary to reset your sequences
193 in the database before further processing.
194
195 ;NEW
196
197 * A first implementation of a Monte Carlo simulation program
198 (ceres - Camera Electronics and REflector Simulation) has been
199 implemented. It can simulate a full telescope already including
200 a complete reflector simulation and a flexible trigger and readout
201 simulation. Currently, no perfect setup is implemented and
202 especially the output of the program (data structure) should
203 be considered alpha state. Also the user interface is not yet
204 ready.
205
206 ;general
207
208 * All command line options after -- are now interpreted as
209 arguments (usually everything which doesn't start with a minus)
210 rather than options (usually everything which starts with a
211 minus). This allows to use file names starting with a -
212
213 * In all resource files you can now initialize the random number
214 generator. For details see: MJob::InitRandomNumberGenerator
215
216 * added a new program called ''readcorsika''. It's purpose is (in analogy
217 to readraw and readdaq) to read a Corsika output file (for now
218 only cherenkov output is supported) and print its contents in a
219 human readable form. It can also write the contents of this file
220 into a root-file.
221
222 * The calculation of the maximum distance to the origin in a MGeomCam
223 has been improved (edges might be further away than the sides).
224 This is just a tiny change but it might change the appearance of
225 the radial profiles a little bit.
226
227 * The default binning of the center-of-gravity plot has slightly been
228 increased
229
230 ;Database
231
232 * Added informations about the DC currents (fMinCurrents, fMedCurrents
233 and fMaxCurrents). The values are retrieved from the plots showing
234 the average DC currents of all pixels versus time.
235
236 * Websites with tables have now the opportunity to remove lines
237 ('-' button at beginning of each line) and get all lines back
238 ('+' at top of the column)
239
240 * Websites: added option to query only sequences containing sumtrigger
241 events
242
243 * Websites: added option to group by date (year, month, night) for runs
244 and sequences and enabled that combining of different group-bys,
245 e.g. status, date and source is possible
246
247 ;automatic analyis
248
249 * Rewritten producing plots in the web.
250 New plots, namely the output of plotoptical.C (extinction curve from
251 KVA), plotstat.C (status of the automatic analysis (percentage of
252 processed, analysed data etc.)) and plotusage.C (statistics of the
253 condor usage in the data center) has been are available now next to the
254 plots of plotdb.C
255 Mean values from the plots (output of the macro) are provided in a
256 txt file now.
257 The creation of the plots for callisto, star and ganymed in the web is
258 now steered via database. Consequently the plots are faster and
259 reliable up-to-date.
260 For all plots, a new layout is available facilitating the browsing
261 through the plots and providing additional information on the
262 displayed values. (tabs.php) These plots are linked from the DB
263 websites and the wiki.
264
265 ;statusdisplay
266
267 * The ''Loop'' entry in the menu bar now contains an option to pause
268 the loop and to process single events.
269
270 ;merpp
271
272 * Fixed merpping of raw-files (the runheader tree got the name RunHeader
273 instead of RunHeaders)
274
275 * Now allows to merpp files newer than 2008/09/03.
276
277 * Added fixes for wrong (wrong or double) run- and file-numbers
278 written by Arehucas. For deatils see MRawRunHeader::FixRunNumbers
279
280 ;callisto
281
282 * Extracting the pulse position for the pulse position check events
283 with sum trigger were denied. This decreased the statistics
284 extremely and therefor the resulting puse position was calculated
285 quite weak. Now sum events pass the calculation if and only if they
286 have also a level 1 trigger.
287
288 * the extraction of pedestal events and pulse position from the
289 first data events is now more automatic and makes sure that
290 a more precise number of events is extracted independent of
291 the ratio with which pedestal events or events with signals
292 are contained in the data.
293
294 * Updated Muon calibration constants for all MUX data (teh changes were
295 all smaller than 5%)
296
297 ;star
298
299 * For the calculation of the effective on time all sum-triggered events
300 were skipped. Now all Level1-triggeres events will pass. This might
301 result in a slight inaccuracy of the effective on time.
302
303 ;ganymed
304
305 * If the source position is more than 1deg away from the camera
306 center an error is raised now.
307
308 * Hopefully fixed the bug ''ganymed crashes when resized''
309
310 ;sponde
311
312 * Fixed a problem which causes the fitted spectral slope to be displayed
313 incorrectly. If you use MJSpectrum::FormFlux in your macros make
314 sure that the parameter 0 of your fit is negative.
315
316 * Added a histogram showing the read source position of your MCs
317
318
319
320== Version 2.1.1 (2008/08/04) ==
321
322 ;Database
323
324 * Added the median number of photo electrons from the calibration
325 pulses to the db (fMedNumPheInner, fMedNumPheOuter) and the relative
326 error of their raw counts (fRelChargeRmsInner, fRelChargeRmsOuter)
327
328 * Added fTotOnTime, which is the on-time as given by the run-headers
329 (in contradiction to fAbsOnTime which comes from CC)
330
331 * Added new primaries for the new data structure (Magic II): for the
332 tables dealing with sequences (SequenceBuild Status, Sequences,
333 SequenceProcessStatus, Calibration, Star and DataSetSequenceProcessing)
334 this is the telescope number (fTelescopeNumber) for the tables dealing
335 with runs (RunData and RunProcessStatus) this is in addition the file
336 number (fFileNumber)
337
338 * Added column fPriority to the status tables to be able to steer the order
339 in which the data is processed. As default the run, sequence and dataset
340 number are used.
341
342 ;automatic analyis
343
344 * Adapted scripts to the new data structure: They can handle now different
345 telescopes (getting the information as usual from the database).
346 The paths for Magic 2 are not yet implemented.
347
348 ;general
349
350 * should work now with root 5.20/00 (please note that root 5.20/00
351 we encounter crahses in the status display which are ot yet
352 understood)
353
354 * Sequences and Datasets are now stored as "MDataSet" and "MSequence"
355 instead of the base name of the file. This makes them easier to
356 access from the code
357
358 * Default Monte Carlo names in MSequence do not require the _E at
359 the end anymore
360
361 * where abrrevating a sequence file with a sequence number is possible
362 also "telescope:sequence" is now accepted, e.g.:
363 star 2:2000123 --out=output
364 see the programs' help for more details.
365
366 * sequences (MSequence or MSequenceSQL) can now directly be retrieved
367 from the database. See the constructors for more details.
368
369 * MReadTree now supports friends
370
371 * MReadTree can now read also files not written by MARS and store
372 the data encapsulated in emulated MParContainers
373
374 * added a new starguider calibration valid since 15.1.08
375
376 ;showplot
377
378 * showplot can now read more than one file at once. This is especially
379 inetersting if reading files containing pure canvases
380
381 ;merpp
382
383 * we merpp the dc currents now also from the camera reports (they have
384 just a lower rate than the current reports, 0.1Hz instead of 1Hz)
385
386 * In the automatic analysis we omit merpping of the currents from the
387 caco files and use the lower rate camera reports from the cc files
388 instead
389
390 * merpp has been redisigned to allow merpping of the cc-reports
391 of a whole sequence. This allows to design a very simple analysis:
392 mkdir output
393 ./callisto 100776 --out=output
394 ./merpp 100776 output
395 ./star 100776 --ind=output --out=output
396 Instead of the sequence number also sequence files are accepted.
397
398 * Implemented a fix for run-numbers between 1001348 and 1001396
399 which were incorrectly assigned by the cc.
400
401
402 ;callisto
403
404 * added a filter again which was was removed in the last release.
405 it removed the most brightest events. This should not change
406 any analysis result because these events are so bright that
407 they cannot be analysed anyway, but the bad-pixel plots doesn't
408 show outliers.
409
410 * updated muon calibration constants for the periods 51-57,
411 58-63 and 67-
412
413 ;star
414
415 * The camera currents are now displayed with the rate of the camera
416 reports instead of the caco reports
417
418 ;ganymed
419
420 * if mc camera files are new enough (>=8) the source position in the
421 camera is now calculated from the stored telscope and shower
422 orientation (Note, that this might not be suitable in all cases
423 depending on the aim of the study. These case still needs
424 implementation)
425
426
427
428== Version 2.1 (2008/06/18) ==
429
430 ;Database
431
432 * introduced average temperature and wind speed from star-files
433
434 * introduced average values from Pyrometer (mainly Cloudiness)
435
436 * introduced the ratio of accepted calibration events in the
437 calibration run
438
439 * introduced the average rates of the different trigger pattern,
440 e.g. the rate of pedestal and calibration events, from the signal-file
441
442 ;general
443
444 * fixed GroupBy options in plot*.C macros
445
446 * only display KVA points (not the Tuorla points) in plotoptical.C
447
448 * all programs now allow to add resources to the ones from the resource
449 file or overwrite them from the command line. This can be done like this
450 ganymed --config=ganymed.rc --rc=Cut1.Param1:0.25 --rc=Cut1.Param3:5.5
451 if something seems to be wrong you can debug what the program is doing
452 using the option --debug-env=3
453
454 * increased the diversity of debug levels. That also means that with -v3
455 you get now less output, i.e. only the output which is important for
456 an analysis. To get more output which helps for debugging try 4, 5 and 6.
457
458 * fixed a problem in the task synchronizing the reading of the reports
459 and the data stream. The effect was that in some circumstances the last
460 events of some trees could have been skipped. Since this is only a
461 very tiny part of the data no severe effect to your analysis results
462 is expected (an exception might be very short, i.e. singel runs,
463 datasets).
464
465 * Dataset file now allow to include the sequence file directly within
466 the dataset file and also allow to exclude single runs from the dataset.
467 (for more details see Class reference of MDataSet)
468
469 * Sequence files now allow for excluding runs from the analysis
470 (for more details see Class reference of MSequence)
471
472 * added code to process the sum-trigger flag
473
474 * the histogram classes MH3 and MHn now support profile histograms
475
476 * the histogram classes MH3 and MHn now support labels at the axis
477
478 * the Random Forest Train-classes (MJTRain*) now store the used datasets
479 in the output file
480
481 * the MFMagicCuts have a new option to allow a linear area cut (for
482 special studies)
483
484 * The liniking of the shared object is now done into a file defined
485 by 'mktemp'. This should be a local file system which accelerates
486 liniking a lot.
487
488 * The code has been prepared for compilation with root 5.18/00d
489
490 * The MHEnergyEst histogram now shows the distribution of
491 (Eest-Emc)/Est and the distributions (Eest-Emc)/Eest vs. Eest
492 and (Eest-Emc)/Emc vs Emc.
493
494 * fixed mars (event display) for merpped raw-data and MC data
495
496 * adapted the synatx of sequence files to allow for the new run/file
497 scheme. For more details see class description of MSequence
498
499 ;showplot
500
501 * Added support for tiff files
502
503 * Added support for csv files (tables containing tab number,
504 name and title)
505
506 * Tabs now can have a title which is displayed in the postscript file
507
508 * When multiple file are written at once (e.g. pngs from a display)
509 it is now possible to use the tab name and or tab number in the
510 file name. For details see showplos's help.
511
512 ;merpp
513
514 * Implemented cc file version 2008-02-20/0
515
516 * Implemented cc file version 2008-05-19/0
517
518 * With new options merpping can be restricted (in addition to the
519 run-number) also by telescope and file number.
520 For details see "merpp --help"
521
522 * Implemented raw data format 11 (the most important change, except
523 from plenty of changes in the format definition, is the addition
524 of the file-number in the header) If nobody makes a mistake this
525 format should have the advantage that it is by definition forward
526 compatible, so old programs will be able to read newer formats.
527
528 * Added Pyrometer information to default output (stored in a new Tree
529 Pyrometer, needs a complete new merpp, i.e. new calibration)
530
531 * Merpping (also update) can now be restricted to one single report.
532 For example:
533 If you want to update an old file with Pyrometer information call
534 merpp --only=Pyrometer --update
535
536 ;callisto
537
538 * in the pedestal processing now at least 50 processed events are
539 required for succeeding.
540
541 * the signal and calib files now contain also the sequence information
542
543 * the two MPedestalCam in the calib file now have proper names
544 to distinguish them from each other (MPedestalCam, MPedestalExtracted)
545
546 * Both pedestal cams now contain the number of events processed
547
548 * In Mars V2.0 the extraction of the fundamental pedestal was broken,
549 i.e. for the extraction of the calibration pulses basically the average
550 over all events of the first slice instead of all slices was used.
551 Since pedestal and calibration constants are continously recalculated
552 this only effected the very first events of every sequence.
553
554 * For the extraction of the position of the maximum sample now the
555 extraction range is set automatically to the extraction window,
556 before the whole accessible range was used.
557
558 * If the number of samples in the events and the number of samples
559 in the run-header disagrees now an error is raised (this can
560 happen in not well simulated Monte Carlo files)
561
562 * In the case of MUX-data pedestal events with the lvl1 trigger flag
563 could survive into the pedestal calculation -- fixed.
564
565 * Tab "TrigPat" added showing the distribution of the trigger pattern
566 as found in the run-files (normalized with the run length)
567
568 * The selection of events from the trigger pattern has been improved.
569 If the trigger pattern is corrupted events won't pass anymore.
570
571 * Added a new command line option --dev-null to suppress output of
572 Y-files (this is useful for test cases)
573
574 * added a new tab "CalPos" showing the arrival time of extracted
575 interleaved calibration events
576
577 ;star
578
579 * the star file now contains also the sequence information
580
581 * Added a new command line option --dev-null to suppress output of
582 I-files (this is useful for test cases)
583
584 * Tab "Rate" added showing the distribution of the trigger pattern
585 (should only be Trig (Lvl1/Lvl2) and Sum (Sum only)) as found in
586 the Y-files (normalized with the run length)
587
588 * The effective on-time calculation doesn't use events with only
589 sum-trigger anymore
590
591 * The data in the MHWeather tab has been reorganized. The never
592 working solar radiation has been removed and the data from
593 the pyrometer (cloudiness, air and sky temperature) is
594 displayed in addition.
595
596 ;ganymed/sponde
597
598 * Now data points are even shown correctly if they have error bars larger
599 than one sigma. Points with null or negative significances are omitted.
600
601 * DrawNicePlot now allows to set a projection range
602
603 * Updates pointing models. One is applied after the implementation
604 of the new LUTS in August, the other one is applied after the
605 next major change of the pointing model in October. Note that
606 these models are preliminary and give wrong results below Zd=65deg
607
608 ;sponde
609
610 * fixed resource files ('''Spectrum''' instead of '''MJSpectrum''')
611
612 * a new option "--force-runtime" is available. In case of very short
613 datasets (for light-curves) which are in the order of a few
614 minutes the calculated effective on-time is not very acurate because
615 it is quantizised in the order of a minute. Therefore you can switch
616 to using the real run-time instead (remakrt: this ignores any
617 dead-time!)
618
619 * a more analytical way is used to "fill" Monte Carlos into regions
620 of impact parameters which have not been simulated because the
621 trigger efficiency is assumed to be 0.
622
623 * estimated sensitivity curves for hi and lo zenith angles are shown
624 scaled to the correct observation time and collection area
625
626 * the Monte Carlo events after cuts are now written to the output file
627 if an output file given
628
629
630
631 *** Version 2.0 (2007/09/03)
632
633 - database: the position used for the pulse pos check was missing
634 in the callisto output and could thus not be filled into the DB.
635 Also the old values seemed not exactly the PulsePos used for
636 teh check.
637
638 - general: Resource file now allow an Include-Resource, i.e. you can
639 read a resource file with default settings, include it in your
640 resource file and overwrite the settings in your file. More than
641 one include file is allowed. Inclusions can be iterative.
642 Include: mydefaults.rc yourdefaults.rc
643 The resources in the first file have higher priority than the
644 second file.
645
646 - general: Now the output files (calib*.root, etc) also contain the
647 resource file (to check it open it in the TBrowser and choose Print()
648 from the context menu)
649
650 - general: Dataset files now allow to overwrite the default path
651 to search for sequence and data files. Note, that the program
652 option and individual resources will overwrite it. For example:
653 SequencePath: /magic/montecarlo/sequences
654 DataPath: /magic/montecarlo/star
655
656 - general: Fixed a problem with variables in MDataPhrase. It seems
657 that only optimdisp (didn't work) was effected.
658
659 - general: Some improvements to the optim and train processing. For
660 example the ststud window now got a proper title.
661
662 - general: The "Status Display: " was removed from the window title
663 within an Eventloop.
664
665 - general: added a new flexible histogram-class (MHn) which can be used
666 for example in testing after optimizations or training to produce
667 user defined histograms.
668
669 - general: The Random Forest now allows attaching an evaluation
670 function which is applied to its output. This allows to train
671 on whatever you like (eg. train on log10(energy), but return
672 energy)
673
674 - general: The Random Forest training of energy (trainenergy.c) and
675 disp (traindisp.C) has been improved by more graphical output to
676 judge the result.
677
678 - general: The training of energy (trainenergy.C) has been improved
679 a lot by training on a different quantity than energy. It gives
680 a result which is highly independant of the source spectrum
681 and shows lower bias than all other options.
682
683 - general: Dataset files are allowed to contain collections of
684 datasets. For more details see the class reference of MDataSet.
685
686 - general: The default WobbleMode in a datset file now (if not
687 overwritten) is "auto", i.e. wobble mode is set if the dataset
688 doesn't contain off-sequences.
689
690 - merpp: Merpp can read file format version 9 now. Please realize
691 that for file format version 9 the extraction range is different
692 and must be set to 0/49 instead of 15/64 in callisto_mux.rc until
693 the first and last 15 slices have been removed from all MUX data.
694
695 - mars: Similar to writing movies you can now select events which
696 should be displayed in your display. Therefore add the following
697 lines to your mars.rc:
698 MFEvtNumber.FileName: ganymed00223552.root
699 MFEvtNumber.Selector: ThetaSquared.fVal<0.04 && DataType.fVal>0.5
700 The input file can be a ganymed-file after (ganymed*.root) or
701 before (ganymed*-summary.root) file. For example to select all events
702 from your on sample after cuts (excluding the ThetaSq cut) use
703 MFEvtNumber.Selector: DataType.fVal>0.5
704 To show all events from your on-sample after quality cuts
705 use the summary file instead.
706
707 - mars: new ways to call mars are implemented. Instead
708 of calling
709 mars filename.root
710 you can now also use
711 mars sequence.txt
712 or
713 mars sequence.txt inputpath
714 or replace sequence.txt by the sequence number if the default
715 sequence file should be used.
716
717 - mars: The default size has been increased
718
719 - mars: There are two new heckboxes which allow to switch off
720 the calculated image parameters
721
722 - callisto: was broken for MCs... fixed.
723
724 - callisto: improved calculation of spline coefficients a lot. This
725 leads to a further improvement of the event rate calibrating MUX
726 data of about 15% (175evt/s instead of 150evt/s)
727
728 - callisto: finally the raw data we read is now real 16bit (with
729 10bit precision) for MUX data and not a stripped 8bit number
730 anymore. Due to scaling of the numbers (without precision loss
731 into an [0-256[ range, the final numbers for pedestal, pedestalrms
732 and extacted signal don't change. However, at all places where
733 raw data is directly accessed (eg. saturation and variation
734 limits in the signal- and pedestal-extraction) the numbers
735 refer still to the data's 16bit range.
736
737 - callisto: The maximum arrival time difference used in the bad
738 pixel treatment is now in units of nanoseconds, which leads to 3.0ns
739 for both, old FADC and MUX-FADC, data.
740
741 - callisto: Be aware that callisto is now calibrating the arrival time
742 in nanoseconds rather than time slices. Also all following tasks
743 have been changed to assume ns units now. If you star data
744 calibrated with an older version it might be necessary to adapt
745 some timimng parameters (Muon Analysis and MFSoftwareTrigger)
746 to obtain optimal results. The plot in the PulsePos tab
747 will now be in ns, too. This might also mean that the Muon
748 analysis in star might not work as perfect as expected as long
749 as old files read in.
750
751 - callisto: The calibration constants of earlier updates got lost
752 somehow. All constants have been updated.
753
754 - star: The PSF is now determined from the profile of the ArcWidth
755 instead of arcwidth/radius. The old way gave to much weight
756 to the bins with low statistics. The reference lines have been
757 updated.
758
759 - star: For speed reasons events suitable for the muon analysis
760 are now also preselected by fConcCOG<0.1 which seems to be a very
761 good preselector for muons.
762
763 - star: is now calculating a new timing parameter the Slope along
764 the major and minor axis of the shower. Therefore a numerical
765 solution of a line-fit is used. To use MHillasExt.fSlopeLong
766 and MHillasExt.fSlopeTrans don't forget to multiply it with
767 the sign stored in MHillasSrc.fCosDeltaAlpha as usual.
768
769 - star: The parameters fInnerSize, fInnerLeakage1 and fInnerLeakage2
770 have been removed from MNewImagePar. They have never been good for
771 anything.
772
773 - star: Implemented a new recursive algorithm which is supposed to be
774 faster. Also implemented new cleaning oiptions, which are:
775 + CleanLevel0:
776 The cleaning level above single core pixels can be kept
777 + KeepIsolatedPixels:
778 Define whether single core pixels should be kept
779 + TimeLevel1:
780 The coincidence window in nanoseconds to single used neighbors
781 + TimeLevel2:
782 The coincidence window in nanoseconds to two used neighbors
783 + PostCleanType:
784 MOde in which a time dependent post cleaning should be applied
785 0: No post cleaning
786 1: Require for each used pixels at least one used neighbor
787 within a time-window of CleanLevel1
788 2: Require for each used pixels at least two used neighbor
789 within a time-window of CleanLevel2
790 3: Require first two and second one used neighbor
791 within a time-window of CleanLevel1 and fCleanLevel2
792 respectively
793 + RecoverIsolatedPixels:
794 - recoveres isolated core pixels if they have a used neighbor
795
796 - mars/star: The new default cleaning is:
797 + CleanLevel1: 6.0
798 + CleanLevel2: 3.0
799 + CleanTime1: 1.75
800 + CleanTime2: 1.75
801 + PostCleanType: 3
802
803 - star/ganymed: The old spark-cuts have been replaced by new ones.
804 These new spark cuts have been cross checked with the sequences
805 84720 (before splitter), 101041 (after splitter) and 223539 (new
806 FADCs). In all cases they seperate pretty well, but of course not
807 perfect. Monte Carlos have suggested to tighten the cuts a little
808 bit further at low sizes. This has been done.
809
810 - ganymed: IMPORTANT - The spark cuts have been changed to match
811 all available data more or less well. This might mean that for
812 YOUR data there are still sparks visible.
813 Whenever you do an analysis you have to make sure that NO sparks
814 survive your cuts!
815
816 - ganymed: The old hadronness and size cuts have gotten new indices
817 (10, 11). The old indices 8 and 9 now mean an additional condition
818 for ghostbusting based on the formula (dist-c[9])*c[8]-slope.
819 If you want to switch off this cut just move the line far away enough,
820 e.g. by setting c[9] to -500. Please update your ganymed.rc files
821 accordingly!
822 The unit of c[9] is deg. It is the dist at which your cut will
823 cross the slope==0. The unit of the slope is ns/deg. So if
824 you readin files calibrated with an older Mars-version you
825 have to adapt the default value for c[9] to the FADCs:
826 - Multiply by two for the MUX FADCs (run number > 200.000)
827 - Multiply by 0.3 for the Siegen FADCs (run number < 200.000)
828 - Multiply by 42 for the meaning of life (run number = 200.000)
829
830 - ganymed: The old Cut0 is now called CutQ and is calculated before
831 the source position is caluclated. If you need a quality cut
832 including source dependant data (be very carefull with this!)
833 you have to use Cut0 instead.
834
835 - ganymed: now properly supports three off regions in wobble mode.
836 It will be the default from now on in ganymed_wobble.rc. To change
837 the number of off-regions use
838 NumOffSourcePositions: 1
839 in your ganymed.rc. Also by default no off-theta cut will be done
840 anymore so that you will get a background level higher than the
841 signal level in your ThetaSq plot for ThetaSq>0.2.
842 Due to this be carefull changing the scaling mode away from
843 "None". You will underestimate your signal if your scale interval
844 is not properly set.
845 (Rem: ThetaSqN is no longer needed)
846
847 - ganymed: is now storing the events of all (on- and off-)
848 source positions even in the case of more than one off-source
849 position. This should allow sponde to work properly and the
850 energy estimation is done correctly in all cases (without any
851 "nearest position" trick)
852
853 - ganymed: From 85340 (19.3.2006) on a real starguider calibration
854 with a real pointing model for the starguider is done, calibrated
855 with more than thousand tpoints taken from this date on.
856
857 - ganymed: was broken for Wobble-MCs... fixed.
858
859 - ganymed: The default cuts (MFMagicCuts) and the disp-parametrization
860 has changed. Note that your old ganymed.rc will be incompatible
861 with the new algorithms! Please check the ganymed.rc files and
862 the class description of MFMagicCuts for more information.
863 It is recommended at the moment to use identical Disp-Parametrizations
864 for on/off- and wobble-mode. If cuts are optimized only
865 the Area-Cut (parameters 2,3,4) and the theta-sq cut (parameter 1)
866 should be optimized. All other values should be kept as they are.
867 If you want to do an anylsis without timing a parameters, you can
868 switch off the timing cuts by seeting parameter 7 to a very small
869 value (eg. -99). To remove the slope parameter from the disp
870 paremtrization set parameter 8 to 0.
871
872 - ganymed: The distribution of observation time versus zenith
873 angle is now shown for off- AND on-data.
874
875 - ganymed: The contents of the source position plot are no longer
876 averaged, thus a lot of (fake) events between the two wobble
877 positions have disappeared.
878
879 - ganymed: There is a new tab "CutT" it contains the VsSize plots
880 with the CutT, whihc is defined in ganymed.rc, applied. It
881 is resonable to use your theta-cut for it, to see if there is
882 something strange (sparks!) in your signal-region.
883
884 - ganymed: To choose a dataset from a collection in a dataset file
885 use the new command line option "--dataset=12345"
886
887 - optim, sponde: should now properly support three off-regions.
888 Just produce your ganymed summary files with three off-regions.
889 optim and sponde will automatically get all off events from
890 all off-regions from this file. Please do not forget to
891 set the scaling in optimwobble.C properly:
892 fit.SetScaleUser(1./3);
893 it is not yet read in automatically (will follow soon).
894 In the case of fixed Scale you can also use
895 cuts.SetThetaCut(MFMagicCuts::kOn);
896 no off-cut needed.
897 Be carefull in case of three off-regions when switching on
898 scale mode. Make sure that the scale interval is set correctly.
899
900 - sponde: sponde.rc and sponde_onoff.rc are now idetical
901
902 - sponde: the resouce files have been rewritten with a lot of
903 comments and a well working parametrization for an energy estimator
904
905 - sponde: In the estimated energy versus monte carlo energy plot the
906 contents where exchanged.... fixed.
907
908 - sponde: the so called "accurate"-mode has been removed. It didn't
909 give any improvement in accuracy, only decreased execution speed.
910
911 - sponde: the so called "simple"-mode has been removed. It didn't
912 give any improvement in simple.
913
914 - sponde: the so called "refill"-mode has been removed. It was anyhow
915 not implemented.
916
917 - sponde: now checks whether the theta distribution of your on-data
918 and the theta-distribution of your Monte Carlo sample (after
919 weighting) fits. If it doesn't fit properly (eg. the Monte Carlo
920 sample is incomplete) execution is stopped. Execution can be forced
921 using the new option --force-theta. Use this option with care!
922
923 - sponde: Proper collection areas can now be constructed also from
924 Monte Carlo samples generated with different maximum impact
925 parameters. Note that in previous version you neither got
926 a warning or failure, nor was there any obvious sign that the
927 collection area was overestimated due to usage of files with
928 different maximum impact parameters.
929
930 - sponde: If MC files with different lower energy limits are used
931 the primary MC spectrum is artificially completed down to the
932 lowest energy used at all. WARNING: that this gives correct
933 collection areas ONLY if none of the events in this region would
934 survive your cuts at all.
935
936 - sponde: the output file now contains more information about
937 the spectrum (eg. the full 2D collection area histogram).
938 Note, that this information can only be written to the file
939 if it is stored automatically via command line argument.
940 If you only store the status display from within the display
941 the information is lost.
942
943 - sponde: added a new tab "Disp". It shows the residual of the disp
944 (Disp-Dist) versus several parameters and it is meant to judge the
945 quality of the disp estimator. In the ideal case the residual is zero
946 and doesn't depend on any variable. The tab is displayed after
947 CutQ and Cut0.
948
949 - sponde: added a new tab "Energy". It shows the residual of the
950 energy (lg(estimated energy)-lg(monte carlo energy)) versus
951 several parameters and it is meant to judge the quality of the
952 energy estimator. In the ideal case the residual is zero
953 and doesn't depend on any variable. In reality even a good estimator
954 can show residuals versus Monte Carlo energy. The tab is displayed
955 after all cuts.
956
957 - sponde: added a new tab "EventDist" showing the unweighted real
958 absolute number of events of your sample after cuts. This tells
959 you how many events with this energy you had in your MC files.
960 The same information you get from the error bars of the weighted
961 histograms, but this is less intuitive.
962
963 - sponde: The spectrum plots now show the crab- and 1553-spectrum
964 for comparison. It is not meant to show these curves in
965 publications, they are only for production.
966
967 - sponde: The OriginalMC tree with the events produced by corsika
968 is now processed only once
969
970 - sponde: Finally fixed most annoying bug, which has effected the
971 last bin of the collection area. It was the problem that binnings
972 of root histograms are from 1 to n (included) but there was a C-like
973 loop in sponde from 0 to n (excluded). Now the loop also includes
974 correctly under- and overflow-bins. The worse thing with this is,
975 that for the events in the highest bin not only the bin-content
976 was wrong, but also the weights applied to these events, which could
977 in pricipal effect also other parts of the distribution (eg. due
978 to energy estimation). Fortunately it effected only a few events
979 in most cases.
980
981
982
983 *** Version 1.2 (2007/05/14)
984
985 - database: The database now has two new values Unsuitable50 and
986 Unsuitable01. They express the number of pixels which are
987 unsuitable for more than 50%, respectively more than 1%, of
988 all calibrated event. It is a more accurate number than the
989 previously used numbers, because they only take the first
990 calibration (ignoring the interleaved calibrations) into account.
991
992 - database: The database now has two other new values UnsuitableMax and
993 DeadMax. They express the maximum number of pixels which were
994 unsuitable, respectively dead, during the sequence. Because
995 of high pedestal rms (cars passing) a few events with very high
996 numbers of unsuitable pixels can happen. Not to suffer from this
997 effect we don't take the highest 0.1% of the numbers into account.
998
999 - general: fixed a bug which caused callisto and star to stop working
1000 properly because the callisto output was currupted
1001
1002 - general: a script called scripts/makemovie has been added which
1003 simplified the process of producing several movies from a single
1004 sequence with different setup.
1005
1006 - callisto: Some more code cleanup. Started to remove old obsolete
1007 code from cvs.
1008
1009 - callisto: The extraction of the pedestal with the extractor was
1010 not random. It seems that extracting at one position is still biased
1011 (for example in the first or last slices we could still suffer from
1012 switching noise) Now it is completely random.
1013
1014 - callisto: In MPedCalcPedRun (which is the pedestal extraction from
1015 pedestal files) individual pixels could be skipped due to high
1016 variations. This was already the case for the pedestal extraction
1017 from the lo-gains since the beginning and properly handled
1018 there, but was introduced in the extraction from the pedestal files
1019 a while ago. To calculate the average value it was still divided
1020 by the number of events procesed not by the number of summands
1021 really summed. This let to a pedestal which was a tiny amount too
1022 small (for a few piels in the order of 0.1%). This led to an slightly
1023 positive offset of the randomly extracted pedestal for a few pixels.
1024 I doubt that this has a big effect on the result, because the effect
1025 on the individual numbers is quite small. Due to this it is suggested
1026 that you rerun your calibration to make sure you are without any
1027 avoidable bias.
1028
1029 - callisto: the ArrTimeRmsLimit is now is a check of the deviation from
1030 the median rms of the absolute arrival time and expressed in significance
1031 levels. This replaces the old meaning of an abolute upper limit. An
1032 absolute upper limit doesn't make much sense, because in our data
1033 all arrival times are shifted at the same time (in fact it might be
1034 a shift of the artificial trigger w.r.t. to the light flash).
1035
1036 - callisto: Added a new tab "BadPixTm" which shows the time evolution
1037 of the number of unsuitable pixels over the whole sequence. This
1038 is usefull mainly to judge if an intermediate calibration had
1039 problems.
1040
1041 - callisto: Added a new tab "DeadPixTm" which shows the time evolution
1042 of the number of dead pixels over the whole sequence. Dead pixels
1043 in this context are unmapped pixels, i.e. pixels which could not
1044 be interpolated, and thus are ignored in the further analysis.
1045
1046 - callisto: It is now possible to use the position of the maximum
1047 of the spline as arrival time instead of the leading edge even
1048 when using the integral for the signal. Therefor set the extraction
1049 type to kIntegralRel ("IntegralRelative") and the relative height
1050 ("HeightTm") to -1:
1051 MJPedestalC1.ExtractSignal.ExtractionType: IntegralRelative
1052 MJPedestalC1.ExtractSignal.HeightTm: -1
1053
1054
1055
1056
1057 *** Version 1.1 (2007/04/27)
1058
1059 - general: The new class MGeomCamDwarf contains the camera geometry
1060 for our prefered Dwarf camera and can be used to create general
1061 geometries of roundish or hexagonal cameras.
1062
1063 - mars: The default cleaning is now abolute 8.5/4.0.
1064
1065 - mars: The resource file mars.rc now contains examples for MUX data
1066
1067 - merpp: Implemented file format version 8 (MUX FADC data). The 16-bit
1068 data containing only 10-bit information is still cooked down to
1069 8-bit, by cutting away the lowest 8-bit.
1070
1071 - merpp: When reading raw data the data is now stored in a single
1072 array. The lo-gain array is obsolete. The interface stays the same.
1073
1074 - callisto: To process the new MUX data use the resource file
1075 callisto_mux.rc
1076
1077 - callisto: The -root and -raw options to read merpped raw data have
1078 been removed
1079
1080 - callisto: If the -mc option is given the sequence-name can now be
1081 replaced by the MC sequence number
1082
1083 - callisto: If the sequence file contains "MonteCarlo: Yes" the
1084 -mc option can now be omitted
1085
1086 - callisto: Started further simplification by removing obsolete
1087 dependancies on MCalibIntensity*Cams.
1088
1089 - callisto: removed unsused intensity calibration from MJCalibration
1090 for further simplification
1091
1092 - callisto: for simplification removed references to
1093 MBadPixelsIntensityCam, MCalibrationIntensityQECam,
1094 MCalibrationIntensityRelTimeCam, MCalibrationIntensityTestCam,
1095 MCalibrationIntensityChargeCam, and MCalibrationIntensityBlindCam
1096 (this should at minimum change nothing at all, and at maximum
1097 improve thing if these containers where somewhere not handled
1098 properly)
1099
1100 - callisto: Added the option to write an event movie. Please use
1101 this option with care (huge files) but exessively to understand
1102 our events. For further documentation please refer to the
1103 IACT wiki
1104 (currently at http://www.astro.uni.wuerzburg.de/mediawiki-1.9.0)
1105
1106 - callisto: Improved binning for the pulse position check histogram
1107
1108 - callisto: The code calculating the pulse position checknow takes
1109 the pedestal into account
1110
1111 - callisto: The arrival time is now stored with full precision this
1112 helps to get rid of artefacts in histograms. For the signal this
1113 is not necessray because it is displayed in log-scale anyhow
1114
1115 - callisto: Fixed a problem with internal exclusions. Pixels which
1116 have once been marked as unsuitable didn't get the necessary
1117 histograms filled anymore to be rechecked with each interleaved
1118 calibration.
1119
1120 - callisto: The relative arrival time resolution (the rms of the
1121 relative arrival time offset) is now checked against its
1122 median and the median deviation, instead of the average
1123 plus an absolute offset.
1124
1125 - callisto: The relative arrival time offset is now calculated
1126 w.r.t. its median not w.r.t. to an artificial reference pixel.
1127
1128 - callisto: The relative time calibration now marks pixels with
1129 outlaying offset as unsuitable
1130
1131 - callisto: The interleaved relative time calibration has been switched
1132 on. The advantage is that pixels which are marked as outliers
1133 now can recover. An improvement over time is not expected, because
1134 the relative time calibration seems stable.
1135
1136 - ganymed: If the dataset file containes "MonteCarlo: Yes" the "-mc"
1137 option can now be omitted.
1138
1139 - ganymed: If either the dataset file containes "MonteCarlo: Yes"
1140 or the option "-mc" is specified as default the monte carlo datacenter
1141 paths (/magic/montecarlo/...) are used if not overwritten in the
1142 dataset file.
1143
1144 - ganymed: The output files now contain run- and event-number for all
1145 events, accessible as RunNumber.fVal and EvtNumber.fVal
1146
1147 - ganymed: Added a plot showing the source position in the camera also
1148 for wobble mode
1149
1150 - ganymed: In addition to the existing task which can be setup to
1151 be executed after Cut1 a final task called "EstimateEnergy"
1152 has been added, executed before writing the final output
1153 (ganymed00000000.root). The task setup in all three cases
1154 can be choosen individually. (For all three(!) cases you
1155 can for example choose MRanForestCalc. For examples see all
1156 sponde*.rc and all ganymed*rc)
1157
1158 - ganymed: If a container "MEstimatedEnergy" is found in the
1159 parameter list (eg. because it was setup by MEstimateEnergy)
1160 it will be written to the output file.
1161
1162
1163
1164 *** Version 1.0 (2007/02/16)
1165
1166 - database: Website to plot values from the database has been added.
1167
1168 - database: The rate of spark events as found by star is now kept
1169 and the rate after cleaning is now with spark events subtracted
1170
1171 - general: The changes to the interpretation of phrases lead to
1172 a problem with the access of MHMatrix objects (eg. "M[0]")... fixed.
1173
1174 - general: Added example files how you can create your own calendar
1175 (eg. as christmas present) with Mars. Just run
1176 root macros/tutorials/calendar.C
1177
1178 - general: Added a possibility to display grouped data in the plotdb.C
1179 macro (and similar macros). This allows to plot hourly, nightly,
1180 weekly, monthly and yearly averages.
1181 For more details see the plotall function of the macro
1182
1183 - general: fixed the error display of the camera display. It showed
1184 wrong results.
1185
1186 - general: fixed a memory leak when reading many MStatusDisplays
1187
1188 - general: added a macro (macros/tutorials/mirrordelay.C) plotting the delay
1189 between a spherical and a parabolic mirror
1190
1191 - callisto: We have a new pulse position check which takes the properties
1192 of the extractor automatically into account. So no need to set
1193 ExtractWinLeft/Right anymore. Again a check for pulses too much to the
1194 left is done. If possible the lo-gain extraction start and hi-gain
1195 extraction end is changed accordingly. If no proper extraction range
1196 can be set (hi-gain too much to the left) an error is raised.
1197
1198 - callisto: New swapped pixels have been found and corrected
1199
1200 - callisto: Redone the signal extraction this includes:
1201 + Unified the algorithms to extract the pedestal for all pedestal
1202 extractions done
1203 + Unification of hi- and lo-gain into one array
1204 + Unification of hi- and lo-gain extraction for Spline and
1205 Digital Filter (means now exactly the same algorithm is used,
1206 not a copy-and-pasted one)
1207 + Store pedestal subtracted data in a common place
1208 + Improved extraction algorithms. If the algorithms search a
1209 maximum but don't find one they don't return the maximum anymore
1210 + Improved the extraction such that a information for signal
1211 and time which is consistent is returned
1212 + replaced the numerical spline with a (not slower) analytical
1213 solution
1214 + Lowered the saturation limit from 250 to 245 to make sure that
1215 we are far away in all pixels from problems with the clock-noise
1216 + The start of the lo-gain extraction is calculated from the hi-gain
1217 arrival time. In case of saturation an estimation is used.
1218 + the hi-gain window was extended to slice 16. This allows extraction
1219 of very late pulses in single pixels or of huge hadron showers.
1220 + Now uses the lo-gain extraction range for pedestal extraction,
1221 not the hi-gain range in the lo-gain
1222
1223 - callisto: New hi-/lo-gain calibration constants have been produced
1224 for all periods from the statistic of the whole period. They are
1225 now used automatically depending on the periods. The old constants
1226 where deviation in avarega about 2%-3%. The constants are very
1227 stable from period to period (<<1%) except for exchanged channels.
1228 In a few cases the constants used so far were off by 1%-2% (maybe
1229 temperature effects?)
1230
1231 - callisto: To gain obsolete space we do not write the
1232 MPedestalFundamental anymore. Also calibration and bad pixel
1233 treatment is not done for it anymore because it has never been used.
1234
1235 - callisto: Fixed a bug in the seuqence handling which caused the
1236 light condition to be ignored
1237
1238 - star: Added two new tabs "Sparkless" and "Sparks" these tabs show
1239 basically the same as "Cleaned" but the distribution devided into
1240 the events fullfilling a spark cut or being rejected by it.
1241 This cut can be changed from star.rc (see example inside) by
1242 the "SparkCut" directive
1243
1244 - star: Star displays now the average individual pixel-rate (IPR) versus
1245 time and the average discriminator threshold (DT) of all pixels.
1246
1247 - optim: fixed a problem with the optim-macros which was due to a bug
1248 in the new phrase parsing
1249
1250 - ganymed: To get a nice FalseSource plot (instead of the all-information
1251 debug plot displayed as a standard plot) use the context menu
1252 somewhere between the two upper plots, click on "DrawNicePlot"
1253 and enjoy the result. (It is the same context menu which contains
1254 the other options)
1255 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1256
1257 - ganymed/optim/train: The cut program, trainings- and optimization
1258 macros could run with less files found than expected from the
1259 sequence-files. No the execution is stopped in this case.
1260
1261 - ganymed: now stores the dataset in the output file with all information
1262 contained (as sequence number, sequence path, data path) so that the
1263 used dataset file can be recreated complete from the output
1264
1265 - sponde: now also allows the uasge of random forest
1266
1267 - sponde: added a plot showing the cut efficiency
1268
1269 - sponde: Using root versions < 5.13/04 still resulted in wrong binomial
1270 errors (eg. effecting the collection area) because the errors of the
1271 two histograms were swapped in the calculation, which makes a difference
1272 in the case the histograms contains weighted events. Aditionally the
1273 totalarea was incorrectly taken into account, which results in too small
1274 errors, which makes a difference at low statistics were the errors
1275 or the collection area dominate.
1276
1277
1278
1279 *** Version 0.10.3 (2006/10/23)
1280
1281 - database: Implemented ObservationMode flag in websites.
1282
1283 - database: For sequences there is now also the stoptime available on the
1284 websites.
1285
1286 - database: Removed ManuallyChanged flag from sequence-info websites,
1287 as it is not needed anymore with the new sequence building algorithm.
1288
1289 - general: MRolke.[cc,h]: Modification of TRolke from root_v5.12.00b.
1290 Class for calculation of confidence intervals (upper limits).
1291 Use model 3 or 4 for upper limit calculation for MAGIC observations.
1292 Please read the class instruction of TRolke for more information.
1293
1294 - general: The programs now return 0xfe if the requested resource file
1295 doesn't exist.
1296
1297 - general: Errors comming from root itself are now not output to
1298 stderr anymore but to our default (colored) log-stream.
1299
1300 - general: Changed the interface to TFormula such that now everything
1301 is parsed by TFormula, which should allow to use phrases even
1302 without paranthesis correctly parsed.
1303
1304 - callisto: replaced the AdHoc number of effective integration slices
1305 in the digital filter by an average of the correct number, averaged
1306 over all possible set of weights. This also gives correct numbers
1307 for the lo-gains which were totally wrong before.
1308
1309 - callisto: drastically reduced memory consumption by not storing
1310 all intermediate calibration results in memory anymore (we might
1311 write them into a file in the future)
1312
1313 - ganymed: To get a nice Theta-Sq plot (instead of the all-information
1314 debug plot displayed as a standard plot) use the context menu
1315 somewhere between the two upper plots, click on "DrawNicePlot"
1316 and enjoy the result. (It is the same context menu which contains
1317 the "DrawAll" option)
1318 PLEASE ALWAYS USE THIS PLOT FOR ANY KIND OF PRESENTATION!
1319
1320
1321
1322 *** Version 0.10.2 (2006/10/15)
1323
1324 - general: changed the building of the sequence files such, that
1325 the source-/project name in case of wobble-sources is not the
1326 source/project of the first data run anymore but the new generalized
1327 wobble source/project
1328
1329 - general: Added some functions to MAstro to calculate sun and
1330 moon properties
1331
1332 - general: Added two new macros (starvisday.C and starvisyear.C)
1333 which allow to plot the visibility of several stars in one day
1334 or of one star along one year
1335
1336
1337
1338 *** Version 0.10.1 (2006/10/11)
1339
1340 - general: HTML logging output was distorted... fixed.
1341
1342 - general: Changed the writing of the sequencefiles such that only
1343 as many pedestal files as giving at least 1000 pedestal events which
1344 are nearby the first calibration run are used as pedestal runs
1345
1346 - sponde: In the calculation of the collection area(s) and the
1347 distribution for MOnte Carlo and estimated energy the error
1348 calculation was wrong because root didn't take the errors
1349 properly into account... fixed.
1350
1351
1352
1353 *** Version 0.10 (2006/10/10)
1354
1355 - general: all executables now check consistency of the root version
1356 installed with the root version used for compilation. The return
1357 code in this case is 255.
1358
1359 - general: The algorithm to build seqeunces has been redesigned
1360 completly. It is now more flexible in terms of a resource file
1361 resources/sequences.rc which can be used to partly overwrite
1362 the default algorithm and defined the important part of the
1363 algorithm. It also takes correctly into account several ways
1364 of taking wobble-data. Currently the new algorithm doesn't take
1365 the number of pedestal events anymore into account (so a sequence
1366 could have much less than 1000 pedestal events and data runs are
1367 no-more used instead)
1368
1369 - general: a lot of small changes to make the code compatible with
1370 root 5.12/00 and gcc 4.1
1371
1372 - general: Fixed some warnings thrown if more warnings are switched
1373 on in the compiler
1374
1375 - general: Added a function to MMath which returns the Median of
1376 the distribution abs(y[i]-median) but at 68:32 division instead
1377 of 50:50, which is somehow the median counterpart of the rms.
1378
1379 - general: MAstroCatalog allows now to read calatog files (as bsc5)
1380 even if they are compressed with gzip (recommended compression
1381 is with "-1")
1382
1383 - showplot:
1384 + batch mode creation of image files now works with root 5.12/00
1385 + added support for writing bmp (though it never produces
1386 bmp which can be read by programs like xv or gimp)
1387 + added support for xml
1388 + added new option to start the display with a different size, by
1389 --display-width=nnn or --display-height=nnn
1390 + added options to define the canvas size when the display is started
1391 --canvas-width=nnn or --canvas-height=nnn
1392 the option can also be used for batch-mode conversion
1393 + added an option which automatically fits the display size to the
1394 desktop-size: --auto-size
1395
1396 - merpp: didn't recognize files with the extension .raw.gz - fixed.
1397
1398 - merpp: allow the reports to have 1000ms due to a bug in the camera
1399 program.
1400
1401 - callisto: New swapped pixels have been found and corrected. For
1402 details see MRawRunHeader::FixAssignment()
1403
1404 - callisto: Callisto now raises an error if one of the input files could
1405 not be opened.
1406
1407 - callisto: In some rare cases it could happen that in the signal
1408 extraction of the digital filter the extractor returned nonsense
1409 results due a wrong initializion of a variable (this happens in
1410 cases in which the extracted signal is exactly zero or the
1411 digital filter couldn't slide because of a too small extraction
1412 window, which could happen in the lo-gain extraction)
1413
1414 - callisto: The lo-gains have been marked as valid in some cases
1415 when they got not extracted at all (deltsumlo=deltatimelo=0) because
1416 the allowed extraction range (fLoGainLast-fLoGainFirst) was
1417 smaller than the number of slices (fLoGainWindowSize) needed
1418 by the lo-gain extractor
1419
1420 - callisto: Updated absolute calibration constants (muon calibration)
1421
1422 - callisto: fixed a bug which caused the hi-gain saturation not
1423 to be handled properly in the spline (the position of the
1424 saturation was calculated incorrectly)
1425
1426 - callisto: fixed a bug which gave weird results if hi- _and_
1427 lo-gain could not be extracted properly. In some cases hi-
1428 and lo-gain have not been extracted at all and the random result
1429 got calibrated. In other cases the hi-gain was saturating and the
1430 lo-gain has not been extracted. For this a completly arbitraty
1431 scale factor was applied to the result from extracting the
1432 charge of the saturating hi-gain.
1433
1434 - callisto: improves handling of extracted signal if lo- and/or
1435 hi-gain could not be extracted properly. If no appropriate
1436 calibration of either the signal or the arrival time is possible
1437 the pixel is now markes as unsuitable instead of estimated.
1438
1439 - callisto: Fixed a problem in the spline extraction which gave
1440 weird results if the signal was extracted from the first (and
1441 highest) slice (as a workaround extraction from the first
1442 slice has been forbidden)
1443
1444 - callisto: Fixed a bug regarding the use of the QE which doesn't
1445 effect the result because the default is used anyhow.
1446 (The bug was there since 14/07/2005)
1447
1448 - callisto: Changed the default for fgLoGainStartShift to -2.4
1449
1450 - callisto: Fixed a bug which caused all hi-/lo-gain calibration
1451 factors to be always 10 for all pixels as soon as the first
1452 calibration update has happend.
1453
1454 - callisto: Fixed the hi-/lo-gain offset for the Digital Filter. It
1455 was off by more than one slice (which gives wrong values for
1456 pixels which have saturated the hi-gain) This was a problem
1457 mainly for timing studies, not so much for the automatic standard
1458 analysis. Also the values for the Spline have been changed slightly:
1459 + Digital Filter from 1.70 to 0.95
1460 + Spline from 1.39 to 1.30
1461 The numbers were sorted out by an extensive test in the
1462 test-database.
1463
1464 - callisto: Removed the tab showing the average calibrated arrival
1465 time. It never gave useful information.
1466
1467 - callisto: Now tab "HiLoCal" which shows the ratio between hi- and
1468 lo-gain pulse for data pulses if hi- and lo-gain have saturated
1469 and both were extracted because the hi-gain was above the
1470 LoGainSwitch.
1471
1472 - callisto: Now tab "HiLoOff" which shows the offset between hi- and
1473 lo-gain pulse position (after application of LoGainOffset, which
1474 means in the ideal case it is 0) for data pulses if hi- and lo-gain
1475 have saturated and both were extracted because the hi-gain was above
1476 the LoGainSwitch.
1477
1478 - callisto: After extensive tests a new threshold level for determination
1479 of the pulse position has been found at 50phe. This is due to the
1480 fact that for lower pulses the arrival time changes its average
1481 behaviour dramatically. It tends to the average of the extraction
1482 range and starts sticking to non-floating point numbers (5, 6, 7, ...)
1483
1484 - callisto: Added two more plots to the calibration part. The average
1485 extracted signal and the average extracted arrival time as
1486 extracted by the signal extractor (This can help debugging problems
1487 because it doesn't involve a fit)
1488
1489 - star: changed the fit for the effective on time such that initial
1490 values are calculated automatically now instead of using build
1491 in values. This makes the fit more indepedant of the underlaying
1492 rates. With a test of ~350 sequences in the test database it could
1493 be shown that the new fit gives the same result +/-1sek.
1494 The highest deviation was +5s the lowest -10s. You can now control
1495 the bahaviour with two resource values:
1496 MHEffectiveOnTime.FistBin: 3
1497 MHEffectiveOnTime.NumEvents: 12000
1498 Use FirstBin=1 and NumEvents=120 to fit the effective on time
1499 from the resulting gamma candidates
1500
1501 - star: The Center histogram in MHHillas is now by default displayed
1502 with the colz draw-option
1503
1504 - ganymed: now produces valid error codes if failed
1505
1506 - ganymed: MFMagicCuts now supports a hadronness cut. Switch it on
1507 with the option "hadronness" instead of "area" or "both" if
1508 you want to use both cuts. The hadronness cut includes a fixed
1509 cut in hadronness (index 8) and a fixed cut in size (index 9).
1510
1511 - ganymed: MFMagicCuts: fixed abug introduced 2005/7/14 which caused
1512 the M3Long of the anti source to be not properly evaluated
1513 (actually is was evaluated as a unique random number) in case
1514 of optimization with anti-theta cut switched on. This might have
1515 lead to improper, but not necessarily wrong, optimization results.
1516
1517 - ganymed: ganymed_onoff.rc, ganymed_wobble.rc - updated with comments
1518 how to use random forest
1519
1520 - ganymed: use the same spark cuts as in ganymed_wobble.rc as in
1521 ganymed_onoff.rc. Seems to be unintentional that they were different.
1522
1523 - sponde: Since the introduction of the possibility to define a
1524 normalization energy instead of using the integral the default
1525 was not using the integral anymore but a normalization energy of
1526 1GeV. It is now the integral again.
1527
1528 - sponde: Fixed a problem in the weighting which did not allow
1529 a MC slope of -1.
1530
1531
1532
1533 *** Version 0.9.6 (2006/05/24)
1534
1535 - general: changed the binning of the azimuthal profile of the camera
1536 such that it is aligned with the 60deg boundaries.
1537
1538 - merpp: better handling of problems with the TH, TD part of the
1539 CC-REPORT for files older than 200507190 and 200412210
1540 respectively
1541
1542 - merpp: improved handling of RECEIVERS-COM-ERROR in CC-REPORT
1543
1544 - merpp: implementd latest changes in starguider reports (sinc 9th May)
1545
1546 - callisto: if an arrival time is extracted outside the fadc range is
1547 was set to the boundary before. Now a random number is assigned
1548 instead to avoid unfortunate coincidences of arrival times just
1549 by this arbitrary value.
1550
1551 - callisto: added a new option to callisto.rc which allows
1552 to set the maximum arrival time difference allowed for the
1553 badpixel algorithm to determin whether a pixels belongs to a shower:
1554 MJCalibrateSignal.MBadPixelsTreat.MaxArrivalTimeDiff: 0.9
1555
1556 - callisto: changed the old value (0.5) for MaxArrivalTimeDiff
1557 to 0.9 as suggested by Stefan due to a recent study on the fraction
1558 of pixels surviving the image cleaning
1559
1560 - callisto: switched off error in case of "pulse is too much to the left"
1561
1562 - callisto: The extraction window is not adapted anymore. This means that
1563 the pulse is extracted from the full range. The draw-back is that the
1564 background (pedestal) will become slightly higher. Switching on/off
1565 the PulsePosCheck in the callisto.rc only effects filling the
1566 histograms.
1567 WARNING: If the pulse is too much to the left data is calibrated!
1568 Check the PulsePosCheck-PulsePosition AND the Inhomogeneity parameter
1569 in the database to make sure that your data is valid!
1570
1571 - star: Show also the number of stars correlated correctly by the
1572 starguider
1573
1574 - ganymed: implemented a new class (MHThetaSqN) which allows to use more
1575 than one off-source region in wobble-mode. To use it add the following to
1576 your ganymed_wobble.rc:
1577 + MJCut.NameHist: MHThetaSqN (switch the new feature on)
1578 + MHThetaSqN.NumOffSourcePos: 3 (define number of off-regions)
1579 + MHThetaSqN.DoOffCut: Yes,No (switch on/off the off-cut)
1580 + Cut1.ThetaCut: None
1581 + MHThetaSqN.SignificanceCutLevel: 2.0 (increase off-cut by 2.0/1.7)
1582
1583 - ganymed: in the case the latest report is older than a default (currently
1584 one minute) and the current report will be skip the starguider
1585 correction and calibration will be reset. The maximum age can be
1586 setup from ganymed.rc by (minutes):
1587 MPointingDevCalc.MaxAge: 1.5
1588
1589 - ganymed: A first implementation showing all size-bins for the theta-sq
1590 resp. alpha-plots in a single tab automatically
1591
1592
1593
1594 *** Version 0.9.5.1 (2006/05/05)
1595
1596 - general: Added a new option "zdiff" to the Makefile which runs
1597 "cvs diff" as "make diff" would do, but with compression
1598
1599 - general: accelerated MTFillMatrix (used for eample in all training
1600 and optimization macros) by skipping some obsolete calles in the
1601 eventloop the first and second loop could be accelerated by ~20%
1602
1603 - general: Added a missing feature in the MFilterList class which
1604 prevented MFEnergySlope from working correctly in trainenergy.C
1605
1606 - general: Accelerated the random forest training and usage a bit
1607
1608 - merpp: Adapted to new raw data file format version 6
1609
1610 - merpp: fixed a problem with reading the starguider reports
1611 after 6.3.2006
1612
1613 - callisto: At some times six pixels had to be exchanged manually in the
1614 data. If the pixels to be swaped are both not found, an error was raised
1615 and calibration was stopped. Now it is assumed they are intentially not
1616 mapped and the Error has been changed to a Warning.
1617
1618 - star: Added new image cleaning based on the arrival time of the shower.
1619 The new cleaning can be accessed using the parameter "Time" instead of
1620 the the old one (like "Absolute) in the star.rc-file.
1621 Recommended parameters:
1622 + MImgCleanStd.CleanLevel1: 8.2
1623 + MImgCleanStd.CleanLevel2: 5
1624 + MImgCleanStd.CleanRings: 2
1625 + MImgCleanStd.KeepSinglePixels: No
1626
1627 - star: Simplified the calculation of the effective on time. By letting
1628 the fit start in the third bin the result should become more stable.
1629 The fit quality is now ignored for the theta-plot which is not used
1630 in the analysis later. Still better pre-cut which, for example,
1631 remove events triggered by car-light (rate changing on a short
1632 time-scale) are missing.
1633
1634 - macros: optimonoff.C, optimwobble.C: implemented a new strategy
1635 for optimization (kWeakSource) which is suggested by the Berlin
1636 people for weak sources.
1637
1638 - macros: plotdb.C:
1639 + if no dataset and no time-interval is given only sequences with
1640 an effective on-time above five minutes are plotted anymore
1641 + added a new tab "RelTime" displaying the relative on-time
1642 (effective on-time divided by the observation time)
1643
1644 - macros: optim*.C: by skipping some obsolete calles in the eventloop
1645 the optimization became a lot faster
1646
1647 - ganymed: In the second loop the MHNewImagePar histograms disapeared.
1648 To display them just delete the pads displayed on top.
1649
1650 - ganymed: fixed a bug which could cause strange behaviour in wobble
1651 mode if no starguider information was available due to an incorrect
1652 initialization of the starguider calibration
1653
1654 - ganymed: The scale region in the False Source Plot (MHDisp) can now
1655 be changed from within the plot. It can also be setup from the
1656 resource file using:
1657 + MHDisp.fScaleMin: 0.325
1658 + MHDisp.fScaleMax: 0.475
1659
1660 - ganymed, showplot: Fixed a problem with the fit to the off-data
1661 (HistOff) which could cause a time lag or an inifinite loop.
1662 The bug did not effect the results at all.
1663
1664 - sponde: Added a new tab showing the effective collection area after
1665 trigger (including the software trigger)
1666
1667 - sponde: MMcSpectrumWeight has a new option which allows to define
1668 the scaling factor not by the integral of the events but at
1669 a defined energy:
1670 e.g. MMcSpectrumWeight.NormEnergy: 200
1671
1672 - MTFillMatrix, sponde: by skipping some obsolete calles in the
1673 eventloops the loop could be accelerated by ~20%
1674
1675
1676
1677 *** Version 0.9.5 (2006/03/13)
1678
1679 - macros: fixed a typo optimwoble.C (SetThetaCut instead SetAlphaCut)
1680 and added the standard Disp-parametrization
1681
1682 - macros: added a new macro datacenter/macros/plotstat.C allowing
1683 to plot statistics about the data processing
1684
1685 - macros: added a new macro to plot the muon correction coefficients
1686 versus period (macros/plot/mucal.C)
1687
1688 - showplot: path inflation for ganymed files was broken
1689
1690 - callisto: Fixed an important bug. When the number of saturating pixels
1691 were calculated the bad pixel information already available from the
1692 calibration was ignored. This yields wrong values in case pixels
1693 are broken and saturate all the time or randomly.
1694
1695 - callisto: Updated Muon calibration constants. Spline data now also uses
1696 different values for different periods
1697
1698 - star: The time-evolution shown in the effective on-time plot now displays
1699 the axis range (if there are no holes it should be similar to the
1700 effective on-time)
1701
1702 - star: Added two new image parameters:
1703 + MNewImagePar.fConcCOG: The ratio of the equivalent signals of
1704 the three pixels next to the center of gravity and the size
1705 + MNewImagePar.fConcCore: The ratio of the signals of all
1706 pixels inside or touching the ellipse and the size
1707
1708 - ganymed: now stops in requested source isn't found in catalog file
1709
1710 - ganymed: Many improvements to the phi-plot in wobble mode:
1711 + with a template the ideal background is displayed
1712 + a possible camera inhomogeneity is taken into account
1713 + the anti theta cut is better supported
1714 + the phi cut is automatically calculated from the theta cut
1715 See the examples in ganymed_wobble.rc for more details.
1716
1717 - ganymed: fixed plot for E^2*dN/dE. The spectrum was multiplied with two
1718 times the bin-width instead of the absolute energy
1719
1720 - ganymed: New cuts for on/off and wobble mode
1721
1722 - ganymed: The smearing of the False Source plot has been increased
1723 to 0.06
1724
1725 - ganymed: The starguider calibration can now be changed from the
1726 resource file.
1727 See the examples in ganymed*.rc for more details.
1728
1729 - ganymed: added a new option for on-/off-observations
1730 MJCut.RandomSourcePosition
1731 If switched on the distribution of observation time of the source
1732 position in the camera is calculated from the on-data and randomly
1733 applied with this distrbution to the off-data.
1734
1735 - ganymed: by skipping some obsolete calles in the eventloop the
1736 first and second loop could be accelerated by ~20%
1737
1738 - ganymed: The default in ganymed_onoff.rc is now to determin the source
1739 position in the off-data randomly according to its distribution in the
1740 on-data.
1741
1742
1743
1744 *** Version 0.9.4.3 (2006/02/13)
1745
1746 - general: Fixed a bug in most of the programs which prevented the
1747 compile date in the startup message to be displayed
1748
1749 - general: Simplified program calls. The following abbreviations
1750 are now possible:
1751 showlog callisto 55599
1752 showplot signal 55599
1753 star 55599
1754 callisto 55999
1755 ganymed 2
1756 In this cases the corrsponding root-, log-, sequence- or dataset-
1757 filename is automatically compiled using the default datacenter
1758 paths ("/magic/*")
1759
1760 - general: Fixed a long outstanding bug which made axis tick marks
1761 disappear if MDataFormula was used (eg. abs(x))
1762
1763 - general: Updated MMath with new functions to calculate the results of
1764 a exponential, logarithmic and powerlaw fits analytically.
1765
1766 - general: Updated some macros with comments:
1767 + macros/optim/optimdisp.C
1768 + macros/optim/optimenergy.C
1769 + macros/optim/optimwobble.C:
1770
1771 - general: MTFillMatrix (the class to fill one or two MHMatrix from
1772 files) now allows adding a pre-cut like in the optimization. E.g. this
1773 is useful to perform g/h-separation cuts before training the random
1774 forest.
1775
1776 - general: Between the rund 53300 and 68754 the pixels 553-558 were not
1777 correctly assigned in the raw data assignement table. A fix to correct
1778 the assignment tabel have been implemented.
1779
1780 - general: MAstroCatalog now allows rotating of the sky-grid and stars
1781 by 90, 180 and 270 deg.
1782
1783 - general: the macro plotdb.C now allows to highlight sequences belonging
1784 to a datset. For more details see the descritions in the macro.
1785
1786 - StatusDisplay: Fixed the algorithm to calculate the size ratio
1787 of the display, it gave wrong results espacially for big sizes.
1788 Now the embedded canvas should always have a ratio width/height=3/2.
1789 The "Size" options have been updated with values fitting the 3/2
1790 size ratio.
1791
1792 - RanForest:
1793 + Updated the random forest classes to support also the
1794 regression method implemented by Thomas H.
1795 + added new tutorial macro how to train the random forest
1796 for energy estimation (macros/optim/rfenergyest.C)
1797 + new classes to train the random forest (still in development)
1798 mjtrain/MJTrainEnergy, mjtrain/MJTrainDisp, mjtrain/MJTrainSeparation
1799 + new tutorial macros for random forest training in macros/train
1800 trainenergy.C, traindisp.C, trainseparation.C
1801
1802 - mars: now allows to setup a cut in the resource file mars.rc to choose
1803 the events to be displayed, eg:
1804 Cut.Condition: {0} && {1}
1805 Cut.0: MHillas.fSize>100
1806 Cut.1: MHillas.fSize<900
1807
1808 - merpp: Made aware of the new .rep format 200510250. This includes
1809 interpretation of the Receiver Board Temperatures (MCameraRecTemp),
1810 the discriminator thresholds (MCameraTD) and the disciminator
1811 delays (MCameraTD). All of them come with the CC report and are therefor
1812 written to the CC tree.
1813
1814 - callisto: fixed a bug in the calculation of the arrival times in
1815 the Digital Filter. They were all shifted by the same amount
1816 fHiGainFirst. This caused an offset in the order of the position of
1817 the left border of the extraction window in the times calculated
1818 from high-gain and from low-gain. The bug effected only the absolute
1819 arrival times. The bug was there since 30.1.2005.
1820
1821 - callisto: Changed the ExtractionWindow for the pulse position check
1822 such that the camera inhomogeneity becomes as less as possible and
1823 comparable to the pulso position check switched off. More details
1824 on the study will be given at our result web-page.
1825
1826 - ganymed: ganymed.rc, ganymed_onoff.rc:
1827 changed to new cuts trained with 1ES1218 and Crab-data
1828 for maximum sigma*log10(excess)
1829
1830 - ganymed: In addition to the Hadronness calculator (CalcHadronness)
1831 a new option was implemented to estimate Disp (CalcDisp)
1832
1833 - ganymed: Implemented two new options which allow
1834 to overwrite the default path to search for the sequence files
1835 --ins=/magic/sequences
1836 and where to search for the image data
1837 --ind=/magic/data/star
1838
1839 - ganymed: MSrcPosCorrect now allows overwriting of the misfocussing
1840 dx/dy from the resource file by
1841 MSrcPosCorrect.Dx
1842 MSrcPosCorrect.Dy
1843
1844 - ganymed: fixed reading the source catalog. Only as many chars
1845 as the requested source name had were compared (If a source
1846 "1ES1218" and "1ES1218+304" were in the catalog and "1ES1218+304"
1847 were requested it could happen that the coordinates of
1848 "1ES1218" were read) The source coordinates are now printed
1849 in addition to its name to the logging output.
1850
1851 - ganymed: changed the background fit in the case of a ThetaSq function
1852 from a polynomial to a exponential, this should give a big improvement
1853 for on-only analysis'
1854
1855 - ganymed/sponde: Calculation of the error of single size-/energy-
1856 bins now uses Li/Ma (5) instead of LiMa (17)
1857
1858 - sponde: Added a plot E^2*dN/dE
1859
1860 - sponde: The energy estimator plot should now show values like
1861 they are commonly used.
1862
1863 - sponde: Now MMcSpectrumWeight also excepts formulas with two X
1864 (a powerlaw with cutoff didn't work before)
1865
1866
1867
1868 *** Version 0.9.4.2 (2005/10/01)
1869
1870 - general: added new tutorial macro macros/tutorials/threshold.C:
1871 how to calculate the threshold
1872
1873 - general: added a new game. Start it from the interpreter with
1874 MagicJam j; (other games are: MineSweeper, MagicSnake, MagicDomino
1875 and MagicReversi)
1876
1877 - general: neighbor pixels in MGeoms are now sorted clockwise
1878
1879 - merpp: made aware of new format 20050829-0
1880
1881 - callisto: New scale factors from muon analysis, stored in new
1882 resource file resources/calibration.rc
1883
1884 - callisto: MBadPixelsCalc now raises an error instead of simply stopping
1885 the eventloop if something went wrong. This is necessary for the
1886 automatic processing
1887
1888 - callisto: Implemented a new treatment for the time information
1889 developed by S.Ruegamer, this should give much better response than
1890 the old very primitive algorithm. This is especially important
1891 for bad pixels due to bright stars as Ceta-Tauri (btw: the old
1892 treatment was buggy! As neighbor pixels to interpolate the
1893 arrival times always the pixels 0 to 5 were taken)
1894
1895 - callisto: In addition to the new treatment of arrival times the
1896 decision of the treatment whether a pixel contains shower
1897 information or not is used to improve the signal interpolation
1898 further. Previously interpolated pixels showed a non-zero signal
1899 do the peak searching signal extractors. Having a signal pixel
1900 beside raised the signal above the cleaning level. Thus the
1901 pixel survived cleaning to often but with a too low mean signal.
1902 By replacing empty pixels with a gaus (mean and rms from the
1903 corresponding Area entries in MPedPhotCam) this effect can
1904 be supressed.
1905
1906 - callisto: The status "unmapped" (for pixel which cannot be interpolated)
1907 got lost when the events were stored by the calibration... fixed.
1908 (This was no problem for normal image cleaning because the pixel
1909 content was artificially set to 0 not surviving standard cleaning
1910 algorithm)
1911
1912 - callisto: Fixed a bug which caused the random and peak-search pedestal
1913 extracted with an extractor to be exchanged for the first (roughly)
1914 500 events (*Extractor and *ExtractorRndm).
1915 (They were simply exchanged in callisto.cc) This bug might have been
1916 introduced in Mars 0.9.4 when the order of calculation of the two
1917 types of pedestal in callisto got exchanged. The bug only effects
1918 the first seconds of data of each sequence.
1919
1920 - star: Taking the arrival time of Muons into account the calculation
1921 of the parameters could be made independant of the noise
1922 (pedestal rms). The dependance was due to the bias of the peak search
1923 extractor. Now only a ZA dependamcy is left which is not yet fully
1924 understood.
1925
1926 - ganymed: The sequences were still not sorted correctly in any case,
1927 because they were sorted by the full qualified path name. Now they
1928 are sorted by their sequence number.
1929
1930 - ganymed: new values for the spark-event-cut
1931
1932 - sponde: required missing MEnergyEst from ganymed.root... fixed.
1933
1934
1935
1936 *** Version 0.9.4.1 (2005/08/18)
1937
1938 - callisto: fixed some problems with the calibration in case of
1939 inteleaved events. Therefor the final and some intermediate
1940 fits are skipped which would take place on partly filled #
1941 histograms and gave wrong results or failed completely.
1942
1943 - callisto: If the intermediate finalization of the histograms
1944 calculating the mean charge of the calibration signal fails
1945 it is counted now and printed in PostProcess of MCalibCalcFromPast.
1946
1947 - ganymed: Fixed some bugs which caused problems in On-only mode.
1948 Still the false source plot doesn't give reasonable results.
1949
1950
1951
1952 *** Version 0.9.4 (2005/08/05)
1953
1954 - general: Fixed the ZA binning. It did not correctly fit the
1955 MC binning
1956
1957 - general: Added a class to correct for the missfocussing in
1958 April (MSrcPosCorrect)
1959
1960 - general: Random Forest energy estimator should now work properly
1961
1962 - general: MHCamera now displays the profiles in deg instead of mm
1963
1964 - general: MH::SetPalette offers a lot of new palettes
1965
1966 - general: MHillas - the case of CorrXY==0 is now handled properly
1967
1968 - general: implemented the possibility to change the line and
1969 marker style of a sky-grid drawn by MAstroCatalog
1970
1971 - general: Runs in sequences and datasets are now automatically
1972 ordered (it is assumed that the order of their filenames correctly
1973 represents the order of observations) to ensure correct reading
1974 of the subsystem data
1975
1976 - general: Runs cannot be added to a sequence twice anymore. Also
1977 Sequences cannot be added twice anymore to a dataset.
1978
1979 - general: fixed a bug in MAstro::Deg2Hms reported by Abelardo.
1980 It gave wrong results by 1./2pi
1981
1982 - showplot: got a new option to start a root interpreter, too
1983
1984 - mars: now displays a rough estimate of Disp and the third moment
1985
1986 - mars: now displays the event time MTime if available
1987
1988 - mars: show muon parameters graphically
1989
1990 - mars: now the file to open can be given as commandline
1991 argument
1992
1993 - merpp: Added support for new arehucas version >= 200507190
1994 implementing values for three temperature sensors in the
1995 counting house (MCameraAUX) and the name of the HV settings file
1996 (MCameraHV).
1997
1998 - merrp: Also fixed some problems with wrong versions numbers stated
1999 by arehucas and implemented some fixed for old versions (<200407070)
2000
2001 - callisto: MCalibrationHiLoCam can now be printed from its context
2002 menu, eg in the TBrowser
2003
2004 - callisto: fixed logain offset (fgOffsetLoGain) from 1.7 to
2005 - 1.39 (MExtractTimeAndChargeSpline)
2006 - 1.40 (MExtractTimeAndChargeDigitalFilter)
2007 This is important mainly for timing studies.
2008
2009 - callisto: Changed limits in MHCalibrationChargeCalc from
2010 - -100.125 to -98 (fgChargeHiGainFirst)
2011 - 1899.875 to 1902. (fgChargeHiGainLast)
2012 - -100.25 to -99 (fgChargeLoGainFirst)
2013 - 899.75 to 901. (fgChargeLoGainLast)
2014 Introduced new limits:
2015 - fgNumLoGainBlackoutLimit: 0.05
2016 - fgLoGainBlackoutLimit: 3.5
2017 - fgLoGainPickupLimit: 3.5
2018
2019 - callisto: The handling of automatic weights for the digital filter
2020 has been improved. There are now new calibration weights special
2021 for Monte Carlo calibrations.
2022
2023 - callisto: Updated Muon scale with latest results (1% difference
2024 for most data, 5% for Mar/Apr'05)
2025
2026 - callisto: use a new criterium to exclude bad pixels: If the high-gain
2027 was saturated and the blackout-events in the low-gain exceed the
2028 fNumLoGainBlackoutLimit, the pixel is declared unsuitable.
2029 This excludes those pixels which have a saturating high-gain
2030 channel, but the low-gain switch does not switch often enough
2031 to make the distribution reliable.
2032
2033 - callisto: fix a bug counting the number of saturated events. Up to now,
2034 the number of saturated slices was counted (which is one for a not too
2035 high number), but for some (pathological) pixels, many more slices
2036 saturated and produced wrong limits.
2037
2038 - callisto: New options in in callisto.rc for MCalibrationRelTimeCalc:
2039 + MCalibrationRelTimeCam.CheckFitResults: Yes
2040 + MCalibrationRelTimeCam.CheckDeviatingBehavior: Yes
2041 + MCalibrationRelTimeCam.CheckHistOverflow: Yes
2042 + MCalibrationRelTimeCam.CheckOscillations: Yes
2043
2044 - callisto: introduce max. number of events for intercalibration,
2045 the rest gets skipped. Default: 4096
2046 The calibration causes too many un-reliable pixels if more
2047 than about 5000 events are treated (@500 Hz) because of the
2048 mode hopping of the VCSels. However, in the past, some
2049 calibration runs have been taken (erroneously) with more
2050 than 5000 events, especially the intensity scans where
2051 a good precision is needed.
2052
2053 - callisto: Set UseExtractorRes to kTRUE, will raise the number of
2054 photo-electrons for the spline extractor by 1-2% (correctly).
2055
2056 - callisto: The intercalibration is now done using a full f-factor
2057 method instead of a simple update. This makes things slower but
2058 more reliable in terms of gain-fluctuations and sudden VCSEL gain
2059 changes.
2060
2061 - callisto: MPedestalY3 now uses the same extraction range as the data
2062 as calculated by MPedestalY2
2063
2064 - callisto: A check of the fraction of allowed unsuitable (10%) and
2065 unreliable (30%) pixels has been addded when the conversion is
2066 calculated from interleaved events
2067
2068 - star: fixed a bug which caused MEffectiveOnTime containers not to
2069 be written. In the worst case they were skipped almost all, in the
2070 best case they were all ok. It depends on how often the new value
2071 was assigned just with an event which was skipped later by another
2072 task
2073
2074 - star: new histograms MHPointing and MHRate
2075
2076 - star: New tab (Currents) displaying the time evolution of the mean
2077 DC currents
2078
2079 - star: New tab (MeanRms) displaying the time volution of the mean
2080 Pedestal Rms
2081
2082 - star: Output now contains MReportStarguider
2083
2084 - star: Improved muon analysis. Due to the absense of a constant
2085 for the gaus fit for arc width and the fact that the arcwidth
2086 plot was a histogram instead of a profile the resulting psf
2087 became pedestal rms dependant
2088
2089 - ganymed: added new plot (MHPhi) for wobble mode as described in
2090 http://www.astro.uni-wuerzburg.de/results/ringmethod/
2091
2092 - ganymed: corrects now (correctly?) for the misspointing in
2093 May/April 05
2094
2095 - ganymed: Two new default templates for ganymed.rc are avilable:
2096 ganymed_onoff.rc and ganymed_wobble.rc
2097
2098 - ganymed: The first version of MFMagicCuts has been released
2099
2100 - ganymed: the Conc1 plot was incorrectly scaled in MHVsSize
2101
2102 - ganymed, sponde: There are two new options to determin the number
2103 of bins for the signal region (NumBinsSignal) and the number of
2104 total bins (NumBinsTotal) in the MHThetaSq histogram
2105
2106 - ganymed: optimized palettes for MHDisp
2107
2108 - ganymed: Fixed an important bug when using ThetaSq as fit function:
2109 The result for the sigma of the gauss(sqrt(x)) fit was a factor
2110 sqrt(2) to large
2111
2112 - ganymed: The false source plot (MHDisp) is now based on Disp
2113 and a background model determined in the first loop is
2114 subtracted
2115
2116 - ganymed: MFMagicCuts are now available in the cvs. The correct
2117 solution for the disp ambiguity problem is now calculated using
2118 the third moment. The third moment cut therefor is skipped.
2119
2120 - ganymed: Output now contains "Disp [MParameterD]" which sign is
2121 already determined by the third moment along the major axis and
2122 so its actual sign is aligned along the major axis of the shower.
2123
2124 - ganymed: If starguider data is available it is taken into account
2125 when calculating the source position. This is especially important
2126 for wobble data at high zenith angles and culmination data.
2127
2128 - ganymed: If available the starguider data is taken into account as
2129 good as it is possible without a starguider calibration. To switch
2130 it off add
2131 MPointingDevCalc.MaxAbsDev: -1
2132 to your ganymed.rc
2133
2134 - sponde: the zenith angle distribution is now weighted instead of
2135 choosen by default. This gurantees higher statistics in the highest
2136 and lowest energy bins. To switch this behaviour off use...
2137
2138 - sponde: now automatically displays the energy threshold
2139
2140
2141
2142 *** Version 0.9.3 (2005/06/03)
2143
2144 - general: MMcEvt now derived from MMcEvtBasic which should
2145 have no influence on compatibility with older camera files
2146
2147 - general: Implemented a new option to MReadReports which allows
2148 to force reading of the first event of some trees (eg. Drive-tree)
2149 before any other tree.
2150
2151 - general: Made a fix to MPointingPosCalc which assumes that the
2152 run-type is real-data if Process is called before ReInit, such
2153 that also the very first Drive-events in a run are treated
2154 correctly.
2155
2156 - shoplot now displays the filename in the title bar of the window
2157
2158 - merpp: new options: --auto-time-start --auto-time-stop which
2159 allow to cut updating with slow-control at the start- or
2160 (previousle --auto-time only allowed: and) stop-time of
2161 the run stored in the runheader.
2162
2163 - callisto: changed default of fgFallTimeHiGain in
2164 MExtractTimeAndChargeSpline from 1.5 to 0.5. 0.5 was
2165 already set as default in callisto_Dec04Jan05.rc
2166
2167 - callisto: the digital filter (MExtractTimeAndChargeDigitalFilter)
2168 now changes the filename for new weights automatically for
2169 cosmics, MC and for different calibration colors.
2170
2171 - callisto: a problem with the order of some code cause the
2172 name of the weights file in MPedestalY2 to be ignored.
2173 Wrongly the calibration_UV weights were used instead
2174 of the cosmics weights set in callisto.rc.
2175
2176 - callisto: should allow ct1 pulser data when the color is
2177 explicitly set also for pretty new runs
2178
2179 - callisto: a new option (MCalibrateData.ScaleFactor) allows
2180 to introduce an additional scale factor (should be around 1)
2181 to adapt for slight deviations in different extractors from
2182 the MC calibration. For MC calibrations the scale factor
2183 is fixed to 1
2184
2185 - callisto: MFCosmics should handle very high signals a bit
2186 more accurate now
2187
2188 - callisto: when calculating the mean pedestal rms for different
2189 pixel sizes or sectors also kUnsuitableEvt is now taken into
2190 account - not only kUnsuitableRun
2191
2192 - callisto: '-raw' option is now the default
2193
2194 - callisto: A dead pixel check has been implemented in MJPedestalC2.
2195 This has the advantage that mean values in the calibration (eg
2196 arrival times) are calculated more accuratly.
2197
2198 - callisto: In the resource file callisto_Dec04Jan05.rc
2199 MJPedestalY2.ExtractWinRight has been reduced from 4.0 to 2.0
2200
2201 - callisto: new Hi-/Lo-Gain intercalibration constants
2202 hilocalib_sp1.root and hilocalib_sp1_mc.root
2203
2204 - callisto: changed default for MJPedestalY2.MaxEvents
2205 from 2000 to 5000 like in callisto_Dec04Jan05.txt
2206
2207 - callisto: in MCalibrationChargeCalc the limit fgPheErrLowerLimit
2208 has changed from 9.0 to 6.0. This is necessary to exclude two very
2209 ringing pixels in September which - when kept - destroy the image
2210 cleaning around them (Markus G.)
2211
2212 - callisto: (!) The Muon analysis of all data taken so far has
2213 suggested that different extractors give slightly different
2214 absolute results after calibration, due to there different
2215 handling of the calibration- and cosmics pulse shape. Although
2216 the over all calibration seems to be a bit to pesimistic (or
2217 the MC seems to be a little bit - 3-5% - too much attenuated).
2218 There for correction factors have been introduced which correct
2219 the calibration constants by
2220 0.956937799 for Digital Filter (callisto.rc)
2221 and
2222 0.904159132 for Spline (callisto_Dec04Jan05.rc)
2223 calibration. The main advantage is, that both data types can
2224 be easily analysed together and compared to the same MC sample.
2225 The factors are choosen such, that the reference is now a
2226 Monte Carlo sample calibrated with Digital Filter (callisto.rc)
2227
2228 - star: fixed a bug which caused the first bin of the histograms
2229 vs time to disapear in PostProcess. This gave wrong results
2230 on the screen. The output and all following programs not
2231 directly accessing the histograms haven't been affected
2232
2233 - star, ganymed: Made sure that always the first Drive-tree event
2234 is read and Processed before the first data event was read.
2235
2236 - ganymed: implemented the possibility to replace the standard
2237 false source plot with a different one. For example: If
2238 you want to use a Disp based FS plot use the resource:
2239 NameHistFS: MHDisp
2240 For details about the requirements of these plots look
2241 at the corresponding classes
2242
2243 - MJOptimize: For On/Off and Wobble optimization MJOptimize
2244 has been replaced by MJOptimizeCuts. To use MHThetaSq instead
2245 of MHAlpha call MJOptimizeCuts("MHThetaSq"). Make sure in this
2246 case MAlphaFitter is setup correctly. For On-Only optimization
2247 MJOptimize has been Replaced by MJOptimizeCuts, too. Call
2248 RunOn() instead of Run(). For energy estimation MJOptimize
2249 has been replaced by MJOptimizeEnergy
2250
2251 - sponde: The input MC spectrum can now be weighted to fake a
2252 different spectrum. This is done via MMcSpectrumWeight. For
2253 more details see the class description and sponde.rc
2254
2255 - sponde: The paremeter comparsion plots are not scaled by
2256 their entries anymore. Instead the MC plot is scaled by using
2257 the result spectrum of the analysis. If the input MC spectrum
2258 and the result spectrum has different slopes the absolut
2259 normalization is normally wrong.
2260
2261
2262
2263 *** Version 0.9.2 (2005/05/20)
2264
2265 - general: Changed the default paths for calibrated data and image
2266 files. (The implemented access to these files doesn't yet exist)
2267
2268 - general: support for MRunIter has been removed from the job classes
2269 (use the setter functions of MSeqeunce instead)
2270
2271 - general: ProcessFile has been renamed to Process in all job classes,
2272 because ProcessFile is missleading
2273
2274 - general: The storage of the palette in MHCamera is now possible
2275
2276 - general: new bits describing unsuitable and unreliable pixels have
2277 been introduced in MBadPixelsPix: kPreviouslyExcluded,
2278 kDeadPedestalRms, kFluctuatingArrivalTimes
2279
2280 - general: fixed reading of CC-REPORTS (weather data) for Arehucas file
2281 versions newer than V200404070
2282
2283 - general: support for cc file versions newer than V200504130. Added
2284 support for active loads (MCameraActiveLoad) and central pixel
2285 (MCameraCentralPixel)
2286
2287 - general: added new histograms for image parameters versus size
2288 (MHVsSize)
2289
2290 - general: The eventloop now automatically calls PrintStatistics
2291
2292 - Status Display: Improved support for printing:
2293 + A default can now be set in .rootrc (for more details see
2294 MStatusDisplay::PrintPS)
2295 + A print dialog is opened so that printer and command line
2296 can be canged
2297
2298 - showlog: improved such that it handles different verbosity levels
2299 more accurate now. This mean you can suppress output when
2300 using showlog.
2301
2302 - showplot: improved
2303 + The new graphics formats have been implemented
2304 (pdf, svg, png, jpg and xpm)
2305 + Implemented an interface for printing. Because you can change
2306 the printing command from the command line you can use all
2307 the nice postscript tool. To print a booklet for example call:
2308 showplot -b --print --print-cmd="cat %f" filename.root | lpr
2309 showplot -b --print --print-cmd="psbook %f | psnup -2 | lpr" filename.root
2310 showplot -b --null --print --print-cmd="psbook %f" filename.root > book.ps
2311
2312 - callisto: fixed a bug in the recognition of the calibration bit
2313 pattern. Concerns only intensity calibration. (The strength of the
2314 intensity has been updated in some cases)
2315
2316 - callisto: add a filter against PIN Diode events when running over
2317 calibration runs since some of the recent calibration runs have
2318 been taken with Pin Diode.
2319
2320 - callisto: added support for the runs 39942, 39944, 44834, 39941,
2321 39943, 44833 in the calibration (MCalibColorSet)
2322
2323 - callisto: MJCalibration.MHCalibrationChargeCam.ProbLimit has
2324 been set to 1e-18 in callisto_Dec04_Jan05.rc
2325
2326 - callisto: in callisto_Dec04Jan05.rc: set value for
2327 MJPedestalY2.MaxEvents from 2000 to 5000 to get better
2328 statistics for the calculation of the mean pulse time
2329 of the cosmisc
2330
2331 - callisto: the charge limit in the calibration has been raised
2332 from 2.5 to 4.5
2333
2334 - callisto: new setup read from callisto.rc
2335 + MCalibCalcFromPast.fNumEventsDump
2336 + MHCalibrationChargeCam.NumHiGainSaturationLimit
2337 + MHCalibrationChargeCam.NumLoGainSaturationLimit
2338
2339 - callisto: MExtractTimeAndChargeSpline extractor:
2340 + The integration ranges were shifted by 0.2 FADC slices to the right.
2341 + unreliable handling of floating point values caused different
2342 results on different platform or with different compiler options:
2343 The new algorithm is numerically exact and more accurate because
2344 it doesn't calculate the integration position by multiple times
2345 adding the step-size (which results in numerical uncertanties
2346 exspecially if multiplied with large numbers)
2347 + A lot of fixes have been introduced which effects integrating the
2348 spline at the edges of the valid range. In this case any memory
2349 was randomly accessed. This behaviour can be tested replacing
2350 all MArrayF by TArrayF which perform a range check (but of course
2351 they are a lot slower)
2352 ! No result obtained with the Spline before can be trusted! Due to
2353 random memory access it might by completely random!
2354
2355 - callisto: set new defaults in MExtractTimeAndChargeDigitalFilter:
2356 + extraction range in the high gain to 4.
2357 + weights file to cosmics_weights46.dat
2358
2359 - callisto:
2360 + introduce the check for fluctuating arrival times.
2361 + set charge limit to from 2.5 to 4.5
2362 + introduce asymmetric exclusion due to "deviating number of phes":
2363 Default: -9.0 +4.5
2364 + make deviating number of phes unsuitable (see David's findings).
2365
2366 - callisto: fixed the display of unsuitable pixels. The old change
2367 to a real profile in MHCamera broke it.
2368
2369 - callisto: The cosmics filter is used in MJCalibration now
2370 independant of the pulser color (formaly it was used only for
2371 CT1-pulser data). The threshold of number of max empty pixels
2372 has been raised from 2% to 5% in MJCalibration. The maximum
2373 fraction of rejected event is 50% otherwise the calibration has
2374 failed. The filter now ignores unsuitable pixels.
2375 Setup the filter from callisto.rc using "ContCosmics"
2376 (see MFCosmics::ReadEnv)
2377
2378 - callisto: changed default for fgOffsetFromLogain back
2379 from -2.8 to -1.8 in digital filter.
2380
2381 - callisto: for the common extractors
2382 + MExtractFixedWindow
2383 * MExtractTimeAndChargeSlidingWindow
2384 * MExtractTimeAndChargeSpline
2385 * MExtractTimeAndChargeDigitalFilter
2386 the hi- and lo-gain reolution is stored in fResolutionPerPheHiGain
2387 and fResolutionPerPheLoGain
2388
2389 - callisto: Updated the hi-/lo-gain intercalibration constants
2390 hilocalib_sp1.root, hilocalib_df46_mc.root, hilocalib_df4.root,
2391 hilocalib_df6.root
2392
2393 - callisto: The default lo-gain extraction window for the
2394 MExtractTimeAndChargeSlidingWindow extractor has been increased
2395 from 6 to 8 to take the stretch of the pusle into account
2396
2397 - callisto (!!!): fixed an important bug in the setting of the
2398 incoming pedestal pointer to the signal extractor extracting
2399 pedestals. This bug caused the pedestals not to be subtracted
2400 correctly in the calibration afterwards. The effect was about 10%
2401 too high conversion factors for the digital filter and the spline
2402 and more than 40% for the sliding window.
2403 The bug existed since end of February! (Markus G.)
2404
2405 - star: added muon support to star. A new tab "MHMuonPar" is
2406 displayed. The lower right plot is an estimate of the point spread
2407 function. A reference value is displayed. To get the real PSF
2408 you must compare with MC. The setup for the muon analysis
2409 is done in star.rc. More informations can be found in
2410 MHSingleMuon and MHCalibParCalc
2411
2412 - star: The weather data is now displayed in star
2413
2414 - star: MEventRateCalc handles the calculation of the event rate more
2415 accurate now in case of the start of a new run inside a sequence
2416
2417 - ganymed: a bug in MSrcPosCalc has been fixed (The changes were taken
2418 from a bugfix of Wolfgang to Loc0LocToCam; Wolfgang: the results are
2419 changed only minimally
2420
2421 - ganymed: (MJCut and MJOptimize) now displayes the number of
2422 excess events versus size. The energy estimation is done in
2423 MJSpectrum (sponde)
2424
2425 - ganymed: got support for using other variables than Alpha, eg. Theta.
2426 Therefor you need a class deriving from MHAlpha which supports
2427 this variable (one is already existing: MHTheta, which is now the
2428 default in ganymed). It is setup through ganymed.rc
2429
2430 - added a full featured spectrum program (sponde) which reads
2431 ganymed output and monte carlos and compiles a spectrum
2432
2433
2434
2435 *** Version 0.9.1 (2005/04/14)
2436
2437 - Fix bug on the arrival time reconstruction when using Digital
2438 Filter (in some marginal cases (10%) times were reconstructed shifted
2439 by 0.2 slices)
2440
2441 - all executables now return 2 where in previous versions -1 has
2442 been returned (gave problems with shell-scripts)
2443
2444 - the Hi-/Lo-Gain intercalibration for monte carlo files is now
2445 also done with a intercalibration input file
2446
2447 - a bug in the time fine adjustment of the digital filter has been fixed
2448
2449 - a lot of small fixes to calling TPad::Divide with a margin==0
2450
2451 - MStatusDisplay now shows the memory usage
2452
2453 - added a memory leak statistic after the eventloop
2454
2455 - MHadronness replaced by MParameterD
2456
2457 - MEnergyEst replaced by MParameterD
2458
2459 - wobble mode can now be switched on from the data-set
2460
2461 - switched on bad pixel detection for a pedestal level
2462 which is more than 5 times the variance
2463
2464 - Fixed default paths to be correct for the new data center
2465
2466 - Fixed handling of drive data. The pointing position in now
2467 copied to MPointingPos inside star for real and MC events
2468
2469 - made sure, that the sequences in a dataset are sorted by
2470 their number to ensure the correct synchronization
2471
2472 - added all resource files necessary to handle spline extraction
2473 of signal for the late 2004 and the early 2005 data
2474
2475 - update the reference lines for the december data
2476
2477 - changed default for fgHiGainFirst from 2 to 0 in spline extractor
2478 This is important for the Dec. and Jan. data where the calibration
2479 pulse position changes much.
2480
2481 - changed default for fgOffsetFromLogain from -1.8 to -2.8 in digital
2482 filter. This corrects only an defective extraction of the MC at
2483 low-gain signals lower than 90 phes.
2484
2485 - fixed some slowdown in calibrating data with interleaved events from
2486 Jan and Dec. As a workaround made the pretty palette the default.
2487 The inverse Deep Blue Sea has a bug which slows down long calibration
2488 runs a lot.
2489
2490 - implemented new values from new starguider report as defined
2491 in TDAS00-07 V7.1 (eg SkyBrighness)
2492
2493 - Fixed the formerly wrong unit of azimuth and zenith angle deviation
2494 in starguider report (If you merpp the same reports with this version
2495 you'll get the correct units (arcmin) but a different result
2496 than with old versions (wrong units))
2497
2498 - Now the status display can also write PNG, JPEG and XPM (other file
2499 formats are still unsupported by root)
2500
2501 - added a lot of scripts and macros in directory datacenter used
2502 for automatic processing
2503
2504
2505
2506 *** Version 0.9 (2005/03/23)
2507
2508 - Calibration is now done autmatically into photo-electrons like
2509 decided by the Collaboration Board
2510
2511 - Reference lines in the display can be read from resource file
2512
2513 - Interlaced calibration events can be handled by callisto
2514
2515 - Hi-Gain vs. Lo-Gain calibration constants can be calculated
2516 and applied in callisto.
2517
2518 - class MJCalibTest can be called by callisto
2519
2520 - callisto can now run with three data types: rawdata, rootdata, MC
2521
2522 - added two classes mreport/MReportStarguider.cc and
2523 mreport/MReportStarguider.h for implementing starguider-data
2524
2525 - the output of merpp-update now contains starguider information:
2526 MReportStarguider and MTimeStarguider
2527
2528 - Fixed bug in MHHadronness.cc which made that the displayed Q-factor
2529 values were lower than they should. This was more visible for high
2530 energy (Size) events.
2531
2532 - Made MExtractTimeAndChargeDigitalFilter the default for callisto
2533
2534 - added a new loop to callisto to support the correct extraction of
2535 the pedestal and pedestal rms through the signal extractor
2536
2537 - added class to perform fourier tranformation of a hexagonal structure
2538 (MHexagonalFT)
2539
2540 - added class to perform fourier tranformation of a hexagonal structure
2541 in a tasklist (MHexagonalFTCalc) example: hft.C
2542
2543 - added class to enhance the MCerPhotEvt from the Magic camera geometry
2544 MGeomCamMagic to a enhanced geometry MGeomCamMagicXT having only
2545 small pixels, example: extendcam.C
2546
2547 - added possibility to write data to memory (TTree) using MWriteRootFile
2548
2549 - added possibility to read a TTree stored only in memory by MReadTree
2550
2551 - new classes to deal with the interleaved calibration events:
2552 MTriggerPattern, MTriggerPatternDecode and MFTriggerPattern
2553
2554 - implemented filters to callisto to skip calibration events
2555
2556 - changed callisto to calculate three kinds of pedestals and pedestal rms:
2557 + fundamental pedestal (MPedPhotFundamental): extracted directly from
2558 the slices by statistics
2559 + pedestal from extractor (MPedPhotFromExtractor): extracted with the
2560 signal extractor without randomization
2561 + random pedestal from extractor (MPedPhotFromExtractorRndm): extracted
2562 with the signal extractor with randomization (extraction window is
2563 randomly fixed)
2564 The three kind of pedestal is not yet implemented (for speed reasons) as
2565 long as nobody really needs it:
2566 + pedestal from extractor with randomizatiuon (MPedPhotFromExtractorRndm):
2567 extracted with the signal extractor with randomization
2568
2569 - callisto now finds the pulse position in the data automatically
2570
2571 - implemented data reduction in calibrated data by reducing the precision
2572 of the stored floating point values (pedestal, rms and signal) to
2573 roughly 0.5%
2574
2575 - fixed showplot to make file format conversion (eg. converting a
2576 status display stored in a root file into a postscript file) in
2577 batch mode possible:
2578 showplot -b --save-as-ps[=outfile.ps] infile.root
2579
2580 - Allow class names as part of filter rules, eg
2581 (MFSupercuts) && (MHillas.fSize>100)
2582
2583 - fixed a lot of stuff to allow all programs to process MonteCarlo
2584 camera files.
2585
2586 - enhanced possibility to debug reading of resource file
2587
2588 - MDataChain should handle priorities of operator more
2589 accurate now
2590
2591 - completely revised the container in which the signal is stored
2592 MCerPhotEvt/Pix, MArrivalTime --> MSignalCam/Pix
2593 * the new implementation is faster and
2594 * needs less storage space
2595
2596 - FIRST version which can process Monte Carlos through the
2597 whole chain of programs (callisto, star, etc)
2598
2599 - implemented new image parameters for the border length of
2600 the shower image (MNewImagePar2)
2601
2602 - implemented wobble-mode in ganymed
2603
2604 - new class (MJOptimize) taking care of all optimization processes
2605
2606
2607
2608 *** Version 0.8.6 (2004/10/05)
2609
2610 - New combined signal and time extractor
2611 MExtractTimeAndChargeDigitalFilter
2612
2613 - The Report for the trigger section in the CC run summary has been
2614 updated, and now the IPRs (Individual Pixel Rates) are available.
2615
2616 - new macros for database interaction: filldotrun.C, filldotrbk.C
2617
2618 - added new program which can convert colored output which was redirected
2619 into a file back into colored text (for example to display it with
2620 more): showlog
2621
2622 - added new program to display an MStatusArray of plots (stored with
2623 MStatusDisplay) from a file: showplot
2624
2625 - Added support for Sequences (MSequence). Sequences are blocks of run
2626 files containing the same calibration and belonging to the same
2627 source
2628
2629 - Added a new task (MTaskEnv) which can be used in setup files to switch
2630 between different tasks (for example to choose a signal extractor)
2631
2632 - Implemented automatic file splitting in MWriteRootFile
2633
2634 - After image cleaning an island index is assigned to all used pixels.
2635 The index corresponds to the order of the islands in size.
2636
2637 - added a cleaning which takes signal height _and_ arrival time into
2638 account: probability cleaning (for more details see MImgCleanStd)
2639
2640 - added a cleaning which takes takes the absolute number of photons
2641 times the area ratio as cleaning level
2642 (for more details see MImgCleanStd)
2643
2644 - Changed calculation of image parameters such, that it can be done
2645 for all used pixels or the pixels with a defined island index only
2646
2647 - implemented new image parameters displaying the number of islands,
2648 saturated hi-gain and lo-gain pixels (MImagePar, MHImagePar)
2649
2650 - event display in executable changed to support also calibrated files
2651 (done with MJCalibrateSignal)
2652
2653 - added program doing the calibration and the signal extraction
2654 and signal calibration: callisto Most part of the setup is done
2655 by a resource file: callisto.rc
2656
2657 - implemented support for pixels with negative IDs (Raw file format
2658 version 4)
2659
2660 - implemented an new option in merpp (--auto-time) to get the time
2661 range for cc and/or caco data from the run header of the raw data
2662
2663 - New star-program (star and MJStar). Taking calibrated data from
2664 callisto/MJCalibrateSignal as input. The setup is done through
2665 a resource file: star.rc
2666
2667 - Added possibility to setup the eventloop in the mars-executable
2668 Camera Display by a resource file: mars.rc
2669
2670 - The the mars-executable Camera Display can now also read
2671 calibrated data files written by callisto/MJCalibrateSignal
2672
2673 - Added a new class which can calculate the source position in
2674 the camera from a pointing model known to be correct and
2675 the pointing model used for observations (MSrcPosFromModel)
2676
2677 - added a new version of the class calculating the effective on-time
2678 MHEffectiveOnTime. It unifies the old classes MHEffOnTime,
2679 MHEffOnTimeTime, MHEffOnTimeTheta, MHTimeDiff, MHTimeDiffTime and
2680 MHTimeDiffTheta.
2681
2682 - added the possibility to count how often a signal is above (or
2683 below) a certain threshold in MHCamEvent and MHCamEventRot (this
2684 can replace MHTriggerLvl0)
2685
2686 - added ore convinient ways to set the axis-titles of your histograms
2687 in your macro to some MH-classes like: MH3, MHVsTime, MHSectorVsTime,
2688 MHPixVsTime, MHVsTime, MHCamEvent and MHCamEventRot
2689
2690
2691
2692 *** Version 0.8.5 (2004/08/06)
2693
2694 - new Signal Extractors: MExtractFixedWindowSpline
2695 and MExtractAmplitudeSpline
2696
2697 - implementes interleave in merpp to be able to merpp parts of a file
2698
2699 - implemented force-functionality to merpp
2700
2701 - star display to display star catalogs (MAstroCatalog)
2702
2703 - star display to 'mirror' stars to the camera (MAstroCamera)
2704
2705 - implemented a new cleaning option which allows cleaning scaled with
2706 the real ratio of the rms depending on the pixel size, not only the
2707 square root of the pixelsize (MImgCleanStd, MCameraData)
2708
2709 - removed obsolete MBlind* classes
2710
2711 - Signal extractor taking the AB flag into account implemented (this makes
2712 an odd number of slices for signal extraction possible
2713 (MExtractSignalABcorr)
2714
2715 - implemented a class extracting the pedestal from the raw-data (events)
2716 itself using empty lo-gain (MpedCalcFromLoGain)
2717
2718 - Added mean values to MPedPhotCam
2719
2720 - Added Makefile for Darwin (this OS is NOT officially supported!)
2721
2722
2723
2724 *** Version 0.8.4 (2004/04/19)
2725
2726 - new fast arrival time extractor using cubic splines:
2727 MExtractTimeFastSpline
2728
2729 - implementes multi-argument support in MDataChain
2730 ("pow(a, b)")
2731
2732 - implemented double reference support in MDataChain
2733 ("MCameraLV.fPowerSupplyA.fVoltagePos5V")
2734
2735 - added support in MF for expressiond like
2736 "MHillas.fWidth<2*<MHillas.fLength"
2737
2738 - MDataChain is now able to support variables like [0], [1], ...
2739 which can be used in fit functions as parameters. The interface
2740 is implemented through the new virtual function
2741 MParContainer::SetVariables
2742
2743 - added new class MArrivalTimeCam/MArrivalTimePix:
2744 Storage containers to hold the ArrivalTime of the camera/pixel
2745
2746 - added new classes for the calibration of relative arrival times:
2747 MCalibrationRelTimePix and MCalibrationRelTimeCam
2748
2749 - added new classes to extract the signal of the blind pixel and the
2750 PIN Diode separately: MExtractBlindPixel and MExtractPINDiode
2751
2752 - added new classes for the bad-pixels treatment (MBadPixels*)
2753 which are more powerfull than the old ones (MBlindPixel*)
2754 and will replace them.
2755
2756 - added filter against cosmics: MFCosmics
2757
2758 - added new class MArrivalTimeCalc2:
2759 Calculates the arrival time as the signal weighted mean of the time
2760 slices in the maximum window
2761
2762 - added a new macro call pointspreadfucntion.C that fits with a 2D
2763 gaussian the DC spot for an star. It gives you the RMS of
2764 the PSF and the center of the star, very useful for misspointing
2765 studies.
2766
2767 - added support for multi-telescope camera files. Added classes
2768 MStereoCalc and MStereoPar, classes to calculate and store shower
2769 parameters calculated from the data of two telescopes, for the MC
2770 studies regarding the MAGIC clone.
2771
2772 - added MMcCalibrationCalc, MMcCalibrationUpdate, classes to obtain
2773 MC data calibrated in photons instead of ADC counts.
2774
2775 - added three macros to show the calibration and analysis chain of
2776 MC data. The macro starmc.C does both calibration and analysis, producing
2777 an output containing Hillas parameters for each event. The macro
2778 mccalibrate.C does just the calibration and writes out a file containing
2779 pixel information in photons instead of FADC data. The macro starmc2.C
2780 reads in such a file and produces an output with Hillas parameters.
2781
2782 - added MPedPhotCalc to compute pedestals in units of photons, see
2783 macro pedphotcalc.C
2784
2785 - added all class to perform the calibration, see macro calibration.C
2786
2787 - added class MFFT to perform Fast Fourier Transforms
2788
2789 - added class MSimulatedAnnealing to perform simulated annealing
2790 minimizations
2791
2792 - added new macro bootcampstandardanalysis.C which holds the skeleton
2793 of the analysis chain discussed in the december bootcamp.
2794
2795 - added support for DAQ raw data file format V2
2796
2797 - implemented an arbitrary time stamp for the events from raw-data
2798 files with file version<3. It is calculated from the run number,
2799 the date of start and the FADC clock tick from the first module
2800
2801 - implemented the correct decoding of the event time-stamp
2802 coming from the DAQ for raw-data files with file-version>2
2803
2804 - added a new classes storing the pedestals in units of photons:
2805 MPedPhotPix, MPedPhotCam
2806
2807 - added support for DC current files from the camera control
2808
2809 - added support for start- and stop-time when merpping report files
2810
2811 - added MReportCC storing the weather data from the CC-REPORT
2812
2813 - added class to fill trainings and test matrices (MTFillMatrix)
2814
2815 - added a filter performing a software trigger (MFSoftwareTrigger)
2816
2817 - Added classes to perform parts of the standard analysis (Jobs):
2818 + MJPedestals
2819 + MJCalibration
2820 + MJExtractSignal
2821 Note: All of them are preliminary!
2822
2823 - Added Iterator to iterate over files giving only the run-number
2824
2825 - Added class (MHSectorVsTime) and example (sectorvstime.C) to plot
2826 the evolution of a sector vs time
2827
2828
2829
2830 *** Version 0.8.3 (2003/12/05)
2831
2832 - adapted Random Forest classes to allow the use with MC
2833 multi-telescope files which can be produced with the coming
2834 camera version 0.7.
2835
2836 - added classes to read and interprete central control report files
2837 (Directory: mreport, Base-Class: MReport, Reader: MReportFileRead, ...)
2838
2839 - enhanced merpp (the executable) to support .raw and .rep files.
2840
2841 - added classes for light calibration (MCalibration* and
2842 MHCalibration*) by Markus Gaug. Further work has to be and will
2843 be done soon.
2844
2845 - Added a preliminary 'synchronizer' (MReadReports) which will
2846 replace MReadMarsFile as soon as it is finished.
2847
2848 - Added a tutorial macro demonstrating how report files are merpped
2849 and how they can be read from the root file in the correct order
2850 of time (readrep.C)
2851
2852 - Added a generalized histogram (similar to MH3) called MVsTime
2853 which allows to plot variables (or rules - MDataChain - of
2854 variables) vs time. For an example have a look at tempvstime.C.
2855
2856 - Changed the name of the event trees:
2857 + Events --> Events
2858 + PedEvents --> Pedestals
2859 + CalEvents --> Calibration
2860
2861 - changed name of MTime in the event trees from MRawEvtTime to MTime
2862
2863 - added displaying the sector indices to the mars event display
2864
2865 - Magic Online Analysis (MOnA) implemented in a first version
2866 (see mona.cc, MOnlineDump and MOnlineDisplay)
2867
2868 - added classes to calculate event rate
2869 (preliminary: MEventRateCalc, MEventRate)
2870
2871 - added new executable 'readdaq' to read *.raw files from the DAQ directly
2872
2873 - added classes dealing with the telescope pointing position (MPointing*)
2874
2875 - implemented the 'final' Mars time stamp based on some experiences with
2876 the new 'Synchonizer'
2877
2878
2879
2880 *** Version 0.8.2 (2003/11/10)
2881
2882 - accelerated standard analysis by a factor of 6-8 ...
2883 + doing precalculations in MGeomCam for the pixel area ratio
2884 + creating a look up table for the single pixels in MCerPhotEvt
2885
2886 - added task to calculates weights in case you want to 'change'
2887 the energy spectrum of a monte carlo file
2888 (MMcWeightEnergySpecCalc - Great work from Marcos Lopez Moya)
2889
2890 - added a new executable star which implements the
2891 star.C macro as precompiled executable. Currently a flexible
2892 setup is not possible, but a 'input card' setup will follow.
2893
2894 - Starting to implement Multi-Telescope-Support based on the
2895 upcomming camera version 0.7. The base for a general support
2896 is implemented and the star-functionality is proven to work.
2897
2898 - Replaced Event-Display in and Camera-Display in the Mars GUI
2899 executable by a more convinient display base on MStatusDisplay.
2900
2901 - fixed the algorithm for the blind pixel treatment (MBlindPixelCalc)
2902
2903
2904
2905 *** Version 0.8.1 (2003/10/20)
2906
2907 - added signal subtraction for pure on data by means of fitting
2908 the background in the off region or by performing a combined
2909 signal/background fit. Provides necessary histograms for
2910 obtaining energy spectra and a light curve.
2911
2912 - added classes to perform and study the selection of the
2913 2nd Level Trigger on MC data (example in triglvl2.C macro)
2914
2915 - added pedestal calculation
2916
2917 - implemented "democratic cleaning" (tail cut value proportional
2918 to pixel area) according to Wolfgang's suggestion.
2919
2920 - added Sigmabar treatment (calculation and basic histogramming)
2921
2922 - added basic routines to apply padding
2923
2924 - added first implementation of MARS-based source visibility plotter
2925 (needs to be linked against slalib, preliminary version)
2926
2927 - enhanced functionality of data chains: random numbers, conversion
2928 functions and access to MHMatrix objects
2929
2930 - fixed some bugs in the CT1 Preproc file reader, which gave wrong
2931 numbers under certain circumstances (runs with 0 events included)
2932
2933 - fixed a bug in the general filter MF (didn't work on some systems
2934 at all)
2935
2936 - fixed a bug in chaining files, which caused the analysis to crash or
2937 ignore files
2938
2939 - implemented more geometry classes describing the parameters used
2940 to simulate the PMT camera
2941
2942 - added new Monte Carlo classes containing the setup of the different
2943 programs in the MC chain.
2944
2945 - added a (preliminary) general task to evaluate chi-square of a given
2946 parameter in an eventloop.
2947
2948 - first implementation of a container describing the observatory
2949 location (Long, Lat, etc)
2950
2951 - added Random Forest - method for g/h-separation
2952
2953 - made compatible with the latest PRO version of root (3.04/02 and 3.05/07)
2954 (this means, that it is compiling, but not yet fully tested)
2955
2956 - added a new status display which can show the present status
2957 of histograms while an eventloop is running (MStatusDisplay,
2958 an example can be found at status.C)
2959
2960 - reorganized directories:
2961 classes describing the image --> mimage
2962 classes containing Monte Carlo Histograms --> mhistmc
2963 classes for Random Forest method --> mranforest
2964
2965 - added (event-)weights to fill histograms
2966
2967 - colors in logging output to screen
2968
2969 - changes to the Image Parameter declaration:
2970 + moved fConc, fConc1 from MHillasSrc to MNewImagePar
2971 + moved fNumUsedPix, fNumCorePix from MHillas to MNewImagePar
2972 + MHillasExt now derives from MParContainer instead of MHillas
2973 --> Files written with the old definition are more or less unreadable
2974
2975 - reading of reflector files
2976
2977 - display data from reflector files in the camera
2978
2979 - implemented currents (and display them in the camera)
2980
2981 - logarithmic scale in camera
2982
2983 - added class to iterate through directory contents (MDirIter)
2984
2985
2986
2987 *** Version 0.8 (2002/11/18)
2988
2989 - added all subdirectories as Include-Paths for ACLIC (s. rootlogon.C)
2990
2991 - corrected 48(!) wrong entries in the Next Neighbor table of the
2992 Magic Camera (all in the inner part of the outer ring, mostly
2993 missing a single NN)
2994
2995 - Fixed a bug in the table describing the Next Neighbours of the
2996 CT1 camera (a pixel 127 doesn't exist and the pixel 126 didn't
2997 have any neighbour)
2998
2999 - changed trigrate.C: now it calculates the pure NSB triggers from
3000 a camera file (generated with no showers), so there is no need
3001 to introduce them by hand in the BgR array (for more details
3002 please ask Abelardo)
3003
3004 - added MHHadronness (and MHadronness) as a general facility to evaluate
3005 the quality of a gamma-hadron seperation method
3006
3007 - changed MWriteAsciiFile to accept rules (MDataChain)
3008
3009 - Calls to MWriteAsciiFile::AddContainer and MWriteAsciiFile::AddRule
3010 must be replaced by calles to MWriteAsciiFile::AddColumn and
3011 MWriteAsciiFile::AddColumns. Be carefull, the arguments have slightly
3012 changed.
3013
3014 - Implemented generalized event-matrices (one row per event)
3015 (MHMatrix)
3016
3017 - implemented the one dimensional composite probabilities
3018 (MHCompProb, MCompProbCalc, comprob.C)
3019
3020 - implemented the Multidimensional Distances (Next Neighbours, Kernel)
3021 (MMultiDimDistCalc, multidimdist.C, multidimdist2.C, MHMatrix)
3022
3023 - Added a camera display displaying the pixel numbers to the
3024 event display gui.
3025
3026 - Added Monte Carlo Informations to event display gui
3027
3028 - Changed the camera display to display the pixel numbering
3029
3030 - Added three buttons to the camera display to change the palette
3031
3032 - Added the number of used and core pixels after image cleaning
3033 to MHillas
3034
3035 - Changed the algorithm used in MHillas according to TDAS 02-03
3036
3037 - Changed the Alpha range according to TDAS 02-03 to [-90°,90°]
3038
3039 - Changed the algorithm used in MHillasSrc according to TDAS 02-03
3040
3041 - Added fCosDeltaAlpha to MHillasSrc
3042
3043 - The numbers of photons used to calculate fConc and fConc1 in
3044 MHillasExt are now scaled with the pixel size, so that one get
3045 a four times smaller value for the bigger pixels in the outer ring.
3046
3047 - added new task to smooth the camera contents (MCameraSmooth)
3048
3049 - added possibility to use interpolated pixel values for blind pixels
3050 instead of removing it completely from the analysis
3051
3052 - Implemented the possibility to save the whole eventloop with
3053 its setup to a file. This information can be read and from
3054 it you can (re)create a Macro. See MEvtLoop::Read, MEvtLoop::Write
3055 and MEvtLoop::MakeMacro. If you find something not working, please
3056 report - this stuff is still in a beta phase.
3057
3058 - MBlindPixelCalc set all Ceta-Tauri pixels to unused not only for the
3059 file having crab starfield, but also for all following files - fixed
3060
3061 - MTaskList::PrintStatistics can now be instructud to print also the
3062 title, too: use PrintStatistics(0, kTRUE)
3063
3064 - Changed the image cleaning so that pixels with to many 'used'
3065 neighbors are left used (to get rid of 'holes' in events)
3066
3067 - Introduced more output to the camera displays
3068
3069 - Added an array of histograms (eg one hist per run), MHArray
3070
3071 - Added a _preliminary_ version of the reader for CT1 PreProc files
3072 (MCT1ReadPreProc)
3073
3074 - Fixed the error calculation of MHMCollectionArea and MHMcIntRate
3075 (thanks to Raquel)
3076
3077 - added the first energy estimator (MEnergyEstParam, estimate.C,
3078 estfit.C) using a parametrization
3079
3080 - Added some new Monte Carlo paremeter containers used to store
3081 setup information from the MC chain (MMcConfigRunHeader,
3082 MMcCorsikaRunHeader, MGeomPMT, MGeomMirror)
3083
3084
3085
3086 *** Version 0.7 (2002/04/30)
3087
3088 - added a bugfix to MCerPhotCalc. In older camera versions (<=40)
3089 the pedestal mean value was saved incorrectly. For files from
3090 this versions we substract 0.5 from the pedestal mean.
3091 WARNING: This may effect your results, so don't wonder...
3092
3093 - First implementation of an algorithm using only triggered events
3094 for the collection area calculation
3095
3096 - Ascii Output can now also be used for parameter containers which
3097 doesn't overload MParCointainer::AsciiWrite
3098
3099 - The Ascii Output is now also capable of writing single data members
3100 of one container
3101
3102 - You are now able to change the order of the values written to the
3103 ascii file
3104
3105 - You can now specify a conversion factor for each data member written
3106 to an ascii file. This may be usefull to change the units of the
3107 data member (eg. degrees instead of millimeters in case of the
3108 hillas parameters)
3109
3110 - Replaced old MHillas by a new structure which allows you to extend
3111 the parameters stored in MHillas very easily:
3112 see MHillas and MHillasExt
3113
3114 - Added classes to handle source dependancy of image parameters:
3115 see MHillasSrc
3116
3117 - Added container (MBinning) to have a standard input for the binning
3118 in different histograms (eg. the Energy bins should be the same in
3119 all histograms)
3120
3121 - Changed Hillas histograms from mm to deg
3122
3123 - Added the flexible binning to the hillas histograms
3124
3125 - Added a filter for the alpha parameter (MFAlpha)
3126
3127 - It is now possible to write single data members of a class object to
3128 an output stream instead of the whole container only
3129
3130 - Added a generalized filter for a data member:
3131 MFDataMember filter("MHillas.fWidth", '<', 0.5);
3132
3133 - Added a generalized Filter parser for more difficult filter rules
3134 MF filter("MHillas.fWidth<0.5 && MHillas.fLength>0.5");
3135
3136 - Added new Monte Carlo histograms:
3137 MHMcEnergyImpact and MHMcEfficiency
3138
3139 - Added many new histograms needed for the flux calculation.
3140
3141 - Added a generalized histograms which can fill and show up to three
3142 data members in either a one-, two- or three-dimensional histogram, eg:
3143 MH3 mh3("MHillas.fWidth", "MHillas.fLength");
3144
3145 - Added:
3146 * calculation of <Theta> as a function of Theta (MHThetabarTheta)
3147 * calculation of <Theta> as a function of time (MHThetabarTime)
3148 they are needed in the flux calculation in
3149 order to select for a given bin in Theta (or time) the appropriate
3150 effective collection area, which is assumed to be given as a function
3151 of Theta and the true energy
3152
3153 - Added calculation of the migration matrix in the energy
3154 (MHMcEnergyMigration):
3155 the migration matrix describes the migration from the true (E_true)
3156 to the estimated energy (E_est); it is needed to determine the
3157 distribution of E_true from the measured distribution of E_est
3158 by unfolding
3159
3160 - changed the color palette in the camera display to DeapSea.
3161
3162
3163
3164 *** Version 0.6 (2002/01/15)
3165
3166 - Introduce the option of disable pixels (MBlindPixels and
3167 MBlindPixelCalc) for the analysis (eg MHillasCalc) to be
3168 able to deal with Star Field NSB.
3169
3170 - Fixed a bug in the pedestals substraction
3171
3172 - Introduced verbosity levels
3173
3174 - Introduced a task (MReadMarsFile) which reads the RunHeader tree, too.
3175
3176 - Fixed several bugs in MFTriggerLvl1 which caused to filter not to
3177 work correctly (thanks to Abelardo)
3178
3179 - Introduced correct treatment of the diffuse Night Sky Background
3180 and NSB (MMcPedestalNSB)
3181
3182 - Corrected treatment of the electronic noise (MMcPedestalCopy)
3183
3184 - Introduced MMcRunHeaders which contains monte carlo run informations
3185
3186 - Added a 'Print'-Task (MPrint) which calls the Print function
3187 of a parameter container for each event
3188
3189 - Removed MHtml (was replaced by THtml of root 3.02) in dohtml.C
3190
3191 - changes to be more efficient with root 3.02/06
3192
3193 - root 3.02/06 fixes:
3194 + the memory leak when reading MRawEvtData
3195 + loosing more time than necessary to update the progress bar
3196
3197 - MWriteAsciiFile is now capable of writing more than one container
3198 in a line. For example: To be able to write Monte Carlo and
3199 Hillas values (energy and alpha) in one line.
3200
3201
3202
3203 *** Version 0.5 (2001/11/06)
3204
3205 - Added new GUI functionality (Analysis)
3206
3207 - Added a camera display to be able to display events in the camera
3208 together with the calculated hillas ellipse
3209
3210 - Added a 'Clone'-Task (MClone) which can clone a parameter container
3211 object at any state of the analysis, so that the output are several
3212 states
3213
3214 - Fixed a bug in the collection area error calculation
3215 (Thanks to Ciro and Abelardo)
3216
3217 - Fixed a bug which causes merpp to crash in some environments
3218
3219 - Implemented auto enabling scheme for Branches to speed up reading
3220 a lot (see MReadTree and MTask)
3221
3222 - Fixed a bug in the Histogram classes which caused histograms to
3223 be written to a file by MWriteRootFile without request
3224
3225 - changed the object I/O from the old stylish root I/O to the new
3226 'auto evolution scheme' This was done only for classes which are not
3227 yet used in Monte Carlo files, so that these files are still readable.
3228
3229 - Added support for a progress bar in MEvtLoop and MReadTree
3230 (see the Analysis Window in Mars for an example)
3231
3232 - Fixed a bug in the package creation which disturbed the conversion
3233 between a mars version unpacked from a tar file and the repository.
3234
3235 - Changed the code to writer merpped (converted into root format)
3236 raw files, to get faster (around 10%)
3237
3238
3239
3240 *** Version 0.4 (2001/09/20)
3241
3242 - This release is made to compile on a root version >= 3.00
3243
3244 - Fixed a bug which causes MReadTree to read the first file only
3245
3246 - Added a task to compute the trigger rate (MMcTriggerRateCalc)
3247
3248 - Added a task to write a container to an Ascii file (MWriteAsciiFile)
3249
3250 - Added a task to write several container to a root file (MWriteRootFile)
3251
3252 - Added calculation of the Enegry Threshold (MMcThresholdCalc)
3253
3254 - Added calculation of the collection area (MMcCollectionAreaCalc)
3255
3256 - fixed some bugs in the Hillas calculation
3257
3258 - added filters to be able to control the task execution dependent on
3259 a parameter (for example: the number of level 1 triggers in a MC-file)
3260
3261
3262
3263 *** Version 0.3 (2001/04/23)
3264
3265 - Many demo macros added
3266
3267 - MCT1ReadAscii is now able to handle more than one file (s. ::AddFile)
3268
3269 - Hillas Calculation added
3270
3271 - Standard image cleaning available
3272
3273 - MReadTree is now able to handle more than one file
3274 (Remark: of the same structure)
3275
3276 - Now we are able to display events in a first version of the
3277 Camera event display. To do this we must run the macro
3278 "macros/readCT1.C" to read data from CT1.
3279
3280
3281
3282 *** Version 0.2 (2001/01/24)
3283
3284 - First Implementation of a Gui to read the raw data. Start the
3285 gui with the command mars.
3286
3287
3288
3289 *** Version 0.1 (2000/12/20)
3290
3291 - First official release 0.1
3292
3293 - Changes:
3294
3295 + changed calling style of MRawPixelIterator from do...while to
3296 while-loop