Changeset 3199 for trunk/MagicSoft/Mars/mjobs/MJCalibration.cc
- Timestamp:
- 02/16/04 15:37:25 (21 years ago)
- File:
-
- 1 edited
Legend:
- Unmodified
- Added
- Removed
-
trunk/MagicSoft/Mars/mjobs/MJCalibration.cc
r3143 r3199 204 204 205 205 // Create histograms to display 206 MHCamera disp1 (geomcam, "Cal;Charge", "Fitted Mean Charges"); 207 MHCamera disp2 (geomcam, "Cal;SigmaCharge", "Sigma of Fitted Charges"); 208 MHCamera disp3 (geomcam, "Cal;FitProb", "Probability of Fit"); 209 MHCamera disp4 (geomcam, "Cal;RSigma", "Reduced Sigmas"); 210 MHCamera disp5 (geomcam, "Cal;RSigma/Charge", "Reduced Sigma per Charge"); 211 MHCamera disp6 (geomcam, "Cal;FFactorPhe", "Nr. of Phe's (F-Factor Method)"); 212 MHCamera disp7 (geomcam, "Cal;FFactorConv", "Conversion Factor (F-Factor Method)"); 213 MHCamera disp8 (geomcam, "Cal;FFactorFFactor", "Total F-Factor (F-Factor Method)"); 214 MHCamera disp9 (geomcam, "Cal;BlindPixPh", "Photon flux inside plexiglass (Blind Pixel Method)"); 215 MHCamera disp10 (geomcam, "Cal;BlindPixConv", "Conversion Factor (Blind Pixel Method)"); 216 MHCamera disp11 (geomcam, "Cal;BlindPixFFactor","Total F-Factor (Blind Pixel Method)"); 217 MHCamera disp12 (geomcam, "Cal;PINDiodePh", "Photons flux outside plexiglass (PIN Diode Method)"); 218 MHCamera disp13 (geomcam, "Cal;PINDiodeConv", "Conversion Factor (PIN Diode Method)"); 219 MHCamera disp14 (geomcam, "Cal;PINDiodeFFactor","Total F-Factor (PIN Diode Method)"); 220 MHCamera disp15 (geomcam, "Cal;Excluded", "Pixels previously excluded"); 221 MHCamera disp16 (geomcam, "Cal;NotFitted", "Pixels that could not be fitted"); 222 MHCamera disp17 (geomcam, "Cal;NotFitValid", "Pixels with not valid fit results"); 223 MHCamera disp18 (geomcam, "Cal;Oscillation", "Oscillating Pixels"); 224 MHCamera disp19 (geomcam, "Cal;Saturation", "Pixels with saturated Hi Gain"); 225 206 MHCamera disp1 (geomcam, "Cal;Charge", "Fitted Mean Charges"); 207 MHCamera disp2 (geomcam, "Cal;SigmaCharge", "Sigma of Fitted Charges"); 208 MHCamera disp3 (geomcam, "Cal;FitProb", "Probability of Fit"); 209 MHCamera disp4 (geomcam, "Cal;RSigma", "Reduced Sigmas"); 210 MHCamera disp5 (geomcam, "Cal;RSigma/Charge", "Reduced Sigma per Charge"); 211 MHCamera disp6 (geomcam, "Cal;FFactorPhe", "Nr. of Phe's (F-Factor Method)"); 212 MHCamera disp7 (geomcam, "Cal;FFactorConv", "Conversion Factor (F-Factor Method)"); 213 MHCamera disp8 (geomcam, "Cal;FFactorFFactor", "Total F-Factor (F-Factor Method)"); 214 MHCamera disp9 (geomcam, "Cal;BlindPixPh", "Photon flux inside plexiglass (Blind Pixel Method)"); 215 MHCamera disp10(geomcam, "Cal;BlindPixConv", "Conversion Factor (Blind Pixel Method)"); 216 MHCamera disp11(geomcam, "Cal;BlindPixFFactor","Total F-Factor (Blind Pixel Method)"); 217 MHCamera disp12(geomcam, "Cal;PINDiodePh", "Photons flux outside plexiglass (PIN Diode Method)"); 218 MHCamera disp13(geomcam, "Cal;PINDiodeConv", "Conversion Factor (PIN Diode Method)"); 219 MHCamera disp14(geomcam, "Cal;PINDiodeFFactor","Total F-Factor (PIN Diode Method)"); 220 MHCamera disp15(geomcam, "Cal;Excluded", "Pixels previously excluded"); 221 MHCamera disp16(geomcam, "Cal;NotFitted", "Pixels that could not be fitted"); 222 MHCamera disp17(geomcam, "Cal;NotFitValid", "Pixels with not valid fit results"); 223 MHCamera disp18(geomcam, "Cal;Oscillation", "Oscillating Pixels"); 224 MHCamera disp19(geomcam, "Cal;Saturation", "Pixels with saturated Hi Gain"); 226 225 227 226 // Fitted charge means and sigmas … … 272 271 disp19.SetCamContent(fCalibrationCam,31); 273 272 274 275 disp1.SetYTitle("Charge [FADC units]"); 276 disp2.SetYTitle("\\sigma_{Charge} [FADC units]"); 277 disp3.SetYTitle("P_{Charge} [1]"); 278 279 disp4.SetYTitle("\\sqrt{\\sigma^{2}_{Charge} - RMS^{2}_{Ped}} [FADC Counts]"); 280 disp5.SetYTitle("Reduced Sigma / Mean Charge [1]"); 281 282 disp6.SetYTitle("Nr. Photo-Electrons [1]"); 283 disp7.SetYTitle("Conversion Factor [PhE/FADC Count]"); 284 disp8.SetYTitle("\\sqrt{N_{PhE}}*\\sigma_{Charge}/\\mu_{Charge} [1]"); 285 286 disp9.SetYTitle("Photon flux [ph/mm^2]"); 287 disp10.SetYTitle("Conversion Factor [Phot/FADC Count]"); 288 disp11.SetYTitle("\\sqrt{N_{Ph}}*\\sigma_{Charge}/\\mu_{Charge} [1]"); 289 290 disp12.SetYTitle("Photon flux [ph/mm^2]"); 291 disp13.SetYTitle("Conversion Factor [Phot/FADC Count]"); 292 disp14.SetYTitle("\\sqrt{N_{Ph}}*\\sigma_{Charge}/\\mu_{Charge} [1]"); 273 disp1.SetYTitle("Q [FADC units]"); 274 disp2.SetYTitle("\\sigma_{Q} [FADC units]"); 275 disp3.SetYTitle("P_{Q} [1]"); 276 277 disp4.SetYTitle("\\sqrt{\\sigma^{2}_{Q} - RMS^{2}_{Ped}} [FADC Counts]"); 278 disp5.SetYTitle("Red.Sigma/<Q> [1]"); 279 280 disp6.SetYTitle("PhE [#]"); 281 disp7.SetYTitle("Conv.Factor [PhE/FADC units]"); 282 disp8.SetYTitle("\\sqrt{N_{PhE}}*\\sigma_{Q}/\\mu_{Q} [1]"); 283 284 disp9.SetYTitle("Phot.flux [ph/mm^{2}]"); 285 disp10.SetYTitle("Conv.Factor [Phot/FADC Count]"); 286 disp11.SetYTitle("\\sqrt{N_{Ph}}*\\sigma_{Q}/\\mu_{Q} [1]"); 287 288 disp12.SetYTitle("Phot.flux [ph/mm^{2}]"); 289 disp13.SetYTitle("Conv.Factor [Phot/FADC Count]"); 290 disp14.SetYTitle("\\sqrt{N_{Ph}}*\\sigma_{Q}/\\mu_{Q} [1]"); 293 291 294 292 disp15.SetYTitle("[1]"); … … 357 355 c8.Divide(1,3); 358 356 359 CamDraw(c8, 1, 4, disp19, 0); 360 357 CamDraw(c8, 1, 1, disp19, 0); 361 358 } 362 359 … … 495 492 // when the calibration hardware-trigger is working) 496 493 // 497 MFCosmics 498 MContinue 494 MFCosmics cosmics; 495 MContinue cont(&cosmics); 499 496 500 497 //
Note:
See TracChangeset
for help on using the changeset viewer.